Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance evaluation of microgrid with extreme learning machine based PID controller

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 4 (2023) · hlm. 1901–1907

DOI
10.11591/eei.v12i4.4029
ISSN
2089-3191, 2302-9285
Terbit
2023-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The enhanced penetration of the renewable energy sources (RES) is dependent on microgrid (MG) to a power system is impact stability of the system due to a variation in dynamic properties of the MG from a traditional generator. As a result, analyzing the new issues with dynamic stability and controlling the operation of the power system in the connection of rising MG penetration becomes critical. This paper contains a MG system with renewable energy assisted, superconducting magnetic energy storage (SMES) storage and an extreme learning machine (ELM) based proportional integral derivative (PID) controller. The effect of renewable-based MG penetration on a dynamic stability and control of the multi machine multi area system under varied operating situations is comprehensively investigated in this study. Non-linear time-domain simulations and several performance indicators are used to evaluate the controller's ability with the different MG penetration percentages under various disturbances and operational conditions.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Manav Rachna International Institute of Research and Studies
  • Ajay Kumar Garg Engineering College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sunanda GuptaManav Rachna International Institute of Research and Studies1
Pratima ManhasManav Rachna International Institute of Research and Studies1
Vasudha AroraManav Rachna International Institute of Research and Studies1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Performance evaluation of microgrid with extreme learning machine based PID controller</dc:title><dc:creator>Isha Rajput</dc:creator><dc:creator>Jyoti Verma</dc:creator><dc:creator>Hemant Ahuja</dc:creator><dc:subject>microgrids</dc:subject><dc:subject>extreme learning machine</dc:subject><dc:subject>PID controller</dc:subject><dc:subject>superconducting magnetic energy storage</dc:subject><dc:subject>renewable energy integration</dc:subject><dc:subject>dynamic stability</dc:subject><dc:subject>controller performance evaluation</dc:subject><dc:subject>nonlinear time-domain simulation</dc:subject><dc:description xml:lang="en">The enhanced penetration of the renewable energy sources (RES) is dependent on microgrid (MG) to a power system is impact stability of the system due to a variation in dynamic properties of the MG from a traditional generator. As a result, analyzing the new issues with dynamic stability and controlling the operation of the power system in the connection of rising MG penetration becomes critical. This paper contains a MG system with renewable energy assisted, superconducting magnetic energy storage (SMES) storage and an extreme learning machine (ELM) based proportional integral derivative (PID) controller. The effect of renewable-based MG penetration on a dynamic stability and control of the multi machine multi area system under varied operating situations is comprehensively investigated in this study. Non-linear time-domain simulations and several performance indicators are used to evaluate the controller's ability with the different MG penetration percentages under various disturbances and operational conditions.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i4.4029</dc:identifier><dc:identifier>10.11591/eei.v12i4.4029</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 4 (2023); 1901-1907</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4029/3284</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>