Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Limits of reactive power compensation of a doubly fed induction generator based wind turbine system

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 5 (2023) · hlm. 2521–2534

DOI
10.11591/eei.v12i5.4968
ISSN
2089-3191, 2302-9285
Terbit
2023-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The doubly fed induction generator (DFIG) systems feature a significant amount of free power capacity that may be used for reactive power adjustment when they are put into practical use. This change, which is occasionally overlooked, is a significant one. Using DFIG systems for wind turbines (WT), this paper explored strategies for reducing and using reactive power. In order to investigate the power characteristic and how it is regulated in DFIG systems, a mathematical model for the steady-state performance of DFIG WT has been developed and presented. Here is a detailed derivation of the limiting range of DFIG's reactive power capacity as well as the physical constraints on reactive power output. The distribution of the DFIG WT at a distribution network's end is demonstrated by a simulation example. Within this simulation, reactive power management strategy, load fluctuation, and the change in wind speed are all taken into consideration. Due to the possibility of a rise in the voltage at the access point, can concluded that both acceptable and efficient to use DFIG WT's reactive power capabilities as an additional continuous reactive power source for effectiveness.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Southern Technical University
  • University of Basrah
  • Shatt Al-Arab University College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Fatimah F. JaberSouthern Technical University1
Haider AlrudainySouthern Technical University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Limits of reactive power compensation of a doubly fed induction generator based wind turbine system</dc:title><dc:creator>Ali Kadhim Abdulabbas</dc:creator><dc:creator>Mazin Abdulelah Alawan</dc:creator><dc:creator>Diyah Kammel Shary</dc:creator><dc:subject>doubly fed induction generator</dc:subject><dc:subject>wind turbines</dc:subject><dc:subject>reactive power compensation</dc:subject><dc:subject>steady-state model</dc:subject><dc:subject>voltage regulation</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>load variation</dc:subject><dc:subject>wind speed variation</dc:subject><dc:description xml:lang="en">The doubly fed induction generator (DFIG) systems feature a significant amount of free power capacity that may be used for reactive power adjustment when they are put into practical use. This change, which is occasionally overlooked, is a significant one. Using DFIG systems for wind turbines (WT), this paper explored strategies for reducing and using reactive power. In order to investigate the power characteristic and how it is regulated in DFIG systems, a mathematical model for the steady-state performance of DFIG WT has been developed and presented. Here is a detailed derivation of the limiting range of DFIG's reactive power capacity as well as the physical constraints on reactive power output. The distribution of the DFIG WT at a distribution network's end is demonstrated by a simulation example. Within this simulation, reactive power management strategy, load fluctuation, and the change in wind speed are all taken into consideration. Due to the possibility of a rise in the voltage at the access point, can concluded that both acceptable and efficient to use DFIG WT's reactive power capabilities as an additional continuous reactive power source for effectiveness.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i5.4968</dc:identifier><dc:identifier>10.11591/eei.v12i5.4968</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2521-2534</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4968/3360</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>