Evaluation of patient electrocardiogram datasets using signal quality indexing

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 2 (2019) · hlm. 519–526

DOI
10.11591/eei.v8i2.1289
ISSN
2089-3191, 2302-9285
Terbit
2019-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Electrocardiogram (ECG) is widely used in the hospital emergency rooms for detecting vital signs, such as heart rate variability and respiratory rate. However, the quality of the ECGs is inconsistent. ECG signals lose information because of noise resulting from motion artifacts. To obtain an accurate information from ECG, signal quality indexing (SQI) is used where acceptable thresholds are set in order to select or eliminate the signals for the subsequent information extraction process. A good evaluation of SQI depends on the R-peak detection quality. Nevertheless, most R-peak detectors in the literature are prone to noise. This paper assessed and compared five peak detectors from different resources. The two best peak detectors were further tested using MIT-BIH arrhythmia database and then used for SQI evaluation. These peak detectors robustly detected the R-peak for signals that include noise. Finally, the overall SQI of three patient datasets, namely, Fantasia, CapnoBase, and MIMIC-II, was conducted by providing the interquartile range (IQR) and median SQI of the signals as the outputs. The evaluation results revealed that the R-peak detectors developed by Clifford and Behar showed accuracies of 98% and 97%, respectively. By introducing SQI and choosing only high-quality ECG signals, more accurate vital sign information will be achieved.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 5 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National University of Malaysia
  • Universiti Teknikal Malaysia Melaka
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rosmina JaafarNational University of Malaysia1
Nur Sabrina RismanNational University of Malaysia1
Khairul Anuar Abdul RahmanUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Evaluation of patient electrocardiogram datasets using signal quality indexing</dc:title><dc:creator>Nazrul Anuar Nayan</dc:creator><dc:creator>Hafifah Ab Hamid</dc:creator><dc:subject>electrocardiogram</dc:subject><dc:subject>signal quality index</dc:subject><dc:subject>R-peak detection</dc:subject><dc:subject>motion artifacts</dc:subject><dc:subject>ECG noise</dc:subject><dc:subject>MIT-BIH arrhythmia database</dc:subject><dc:subject>vital signs monitoring</dc:subject><dc:subject>MIMIC-II</dc:subject><dc:subject>fantasia</dc:subject><dc:description xml:lang="en">Electrocardiogram (ECG) is widely used in the hospital emergency rooms for detecting vital signs, such as heart rate variability and respiratory rate. However, the quality of the ECGs is inconsistent. ECG signals lose information because of noise resulting from motion artifacts. To obtain an accurate information from ECG, signal quality indexing (SQI) is used where acceptable thresholds are set in order to select or eliminate the signals for the subsequent information extraction process. A good evaluation of SQI depends on the R-peak detection quality. Nevertheless, most R-peak detectors in the literature are prone to noise. This paper assessed and compared five peak detectors from different resources. The two best peak detectors were further tested using MIT-BIH arrhythmia database and then used for SQI evaluation. These peak detectors robustly detected the R-peak for signals that include noise. Finally, the overall SQI of three patient datasets, namely, Fantasia, CapnoBase, and MIMIC-II, was conducted by providing the interquartile range (IQR) and median SQI of the signals as the outputs. The evaluation results revealed that the R-peak detectors developed by Clifford and Behar showed accuracies of 98% and 97%, respectively. By introducing SQI and choosing only high-quality ECG signals, more accurate vital sign information will be achieved.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i2.1289</dc:identifier><dc:identifier>10.11591/eei.v8i2.1289</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 2 (2019); 519-526</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1289/1180</dc:relation></oai_dc:dc>