Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Improved modified a multi-level inverter with a minimum total harmonic distortion

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 2 (2022) · hlm. 672–680

DOI
10.11591/eei.v11i2.3466
ISSN
2089-3191, 2302-9285
Terbit
2022-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Renewable energy sources are developed as a result of the increased demand for electrical power. The nature of the solar energy source is DC. The DC source for many applications needs to be converted to AC. The inverter is used to convert the power from DC to AC. Total harmonic distortion (THD) is a significant concern with inverters. Multi-level inverters are used to reduce the THD. The stair output voltage of the multi-level inverter not only reduces the THD but also reduces the switches' stresses, so a low voltage rating can be used for the switches. In this paper, a modified inverter topology is introduced in which the number of switches is reduced for the same number of output voltage levels, which leads to reducing the losses and the cost. To reduce the THD, different amplitudes for the carrier signals that control the switches in each level are suggested. Another method to reduce the THD by using different capacitor values across the input DC source is presented. The MATLAB/Simulink is used to show the validity of the suggested modified topology and the modifications.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Basrah
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Basim Talib KadhemUniversity of Basrah2
Sumer Sahib HardenAfiliasi tidak diketahui1
Osama Yaseen Khudair AlatbeeAfiliasi tidak diketahui1
Sumer S. HardanUniversity of Basrah1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Improved modified a multi-level inverter with a minimum total harmonic distortion</dc:title><dc:creator>Khalid M. Abdulhassan</dc:creator><dc:creator>Osama Yaseen Khudair Al-Atbee</dc:creator><dc:subject>multilevel inverter</dc:subject><dc:subject>total harmonic distortion reduction</dc:subject><dc:subject>reduced switch count</dc:subject><dc:subject>DC-AC conversion</dc:subject><dc:subject>solar energy</dc:subject><dc:subject>switch stress reduction</dc:subject><dc:description xml:lang="en">Renewable energy sources are developed as a result of the increased demand for electrical power. The nature of the solar energy source is DC. The DC source for many applications needs to be converted to AC. The inverter is used to convert the power from DC to AC. Total harmonic distortion (THD) is a significant concern with inverters. Multi-level inverters are used to reduce the THD. The stair output voltage of the multi-level inverter not only reduces the THD but also reduces the switches' stresses, so a low voltage rating can be used for the switches. In this paper, a modified inverter topology is introduced in which the number of switches is reduced for the same number of output voltage levels, which leads to reducing the losses and the cost. To reduce the THD, different amplitudes for the carrier signals that control the switches in each level are suggested. Another method to reduce the THD by using different capacitor values across the input DC source is presented. The MATLAB/Simulink is used to show the validity of the suggested modified topology and the modifications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i2.3466</dc:identifier><dc:identifier>10.11591/eei.v11i2.3466</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 2 (2022); 672-680</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3466/2543</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>