Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Reconfiguration with Simultaneous DG installation to Improve the Voltage Profile in Distribution Network using Harmony Search Algorithm

Bulletin of Electrical Engineering and Informatics · Vol. 4 No. 4 (2015) · hlm. 257–273

DOI
10.11591/eei.v4i4.509
ISSN
2089-3191, 2302-9285
Terbit
2015-08-24
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Due to dynamic nature of loads, total system load is more than its generation capacity that makes relieving of load on the feeders not possible and hence voltage profile of the system will not be improved to the required level. In order to meet required level of load demand, Reconfiguration DG units are integrated in distribution network to improve voltage profile, to provide reliable and uninterrupted power supply and also to achieve economic benefits such as minimum power loss, energy efficiency and load leveling. This work proposes minimization of real power losses and improvement of voltage profile using network reconfiguration in the presence of distributed generation. Generally distributed generations (DG) are preferred with objective of minimizing real power loss and improving voltage profile in distribution system. In this work A meta heuristic Harmony Search Algorithm (HSA) is used to simultaneously reconfigure and identify the optimal locations for installation of DG units in a distribution network. Sensitivity analysis is used to identify optimal locations for installation of DG units. The proposed method has tested in MATLAB for 33-bus and 69- Bus radial distribution systems at three different load levels and the analysis is presented for loss minimization.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jawaharlal Nehru Technological University Anantapur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kuruva Siva RamuduAfiliasi tidak diketahui1
Mareddy Padma LalithaJawaharlal Nehru Technological University Anantapur1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Reconfiguration with Simultaneous DG installation to Improve the Voltage Profile in Distribution Network using Harmony Search Algorithm</dc:title><dc:creator>S. Muqthiar Ali</dc:creator><dc:creator>P. Suresh Babu</dc:creator><dc:creator>B. Gurusekhar</dc:creator><dc:subject>distribution network reconfiguration</dc:subject><dc:subject>distributed generation</dc:subject><dc:subject>voltage profile improvement</dc:subject><dc:subject>power loss reduction</dc:subject><dc:subject>harmony search algorithm</dc:subject><dc:subject>optimal DG placement</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>sensitivity analysis</dc:subject><dc:subject>metaheuristic optimization</dc:subject><dc:description xml:lang="en">Due to dynamic nature of loads, total system load is more than its generation capacity that makes relieving of load on the feeders not possible and hence voltage profile of the system will not be improved to the required level. In order to meet required level of load demand, Reconfiguration DG units are integrated in distribution network to improve voltage profile, to provide reliable and uninterrupted power supply and also to achieve economic benefits such as minimum power loss, energy efficiency and load leveling. This work proposes minimization of real power losses and improvement of voltage profile using network reconfiguration in the presence of distributed generation. Generally distributed generations (DG) are preferred with objective of minimizing real power loss and improving voltage profile in distribution system. In this work A meta heuristic Harmony Search Algorithm (HSA) is used to simultaneously reconfigure and identify the optimal locations for installation of DG units in a distribution network. Sensitivity analysis is used to identify optimal locations for installation of DG units. The proposed method has tested in MATLAB for 33-bus and 69- Bus radial distribution systems at three different load levels and the analysis is presented for loss minimization.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2015-08-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v4i4.509</dc:identifier><dc:identifier>10.11591/eei.v4i4.509</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 4 No 4 (2015); 257-273</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>