Abstrak

The increased awareness in reducing energy consumption and encouraging response from the use of smart meters have triggered the idea of non-intrusive load monitoring (NILM). The purpose of NILM is to obtain useful information about the usage of electrical appliances usually measured at the main entrance of electricity to obtain aggregate power signal by using a smart meter. The load operating states based on the on/off loads can be detected by analysing the aggregate power signals. This paper presents a comparative study for evaluating the performance of artificial intelligence techniques in classifying the type and operating states of three load types that are usually available in commercial buildings, such as fluorescent light, air-conditioner and personal computer. In this NILM study, experiments were carried out to collect information of the load usage pattern by using a commercial smart meter. From the power parameters captured by the smart meter, effective signal analysis has been done using the time time (TT)-transform to achieve accurate load disaggregation. Load feature selection is also considered by using three power parameters which are real power, reactive power and the TT-transform parameters. These three parameters are used as inputs for training the artificial intelligence techniques in classifying the type and operating states of the loads. The load classification results showed that the proposed extreme learning machine (ELM) technique has successfully achieved high accuracy and fast learning compared with artificial neural network and support vector machine. Based on validation results, ELM achieved the highest load classification with 100% accuracy for data sampled at 1 minute time interval.

Kata kunci

Jaringan kolaborasi para penulis

27 penulis · 82 tautan kepenulisan bersama · 44 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • United Arab Emirates University
  • National University of Malaysia
  • Western Sydney University
  • University of Technology Malaysia
  • Universiti Teknikal Malaysia Melaka
  • Nanyang Technological University
  • Northern Technical University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S.N. KhalidUniversity of Technology Malaysia4
Madathodika AsnaUnited Arab Emirates University2
Aziah KhamisUniversiti Teknikal Malaysia Melaka1
Yan Hui XuNanyang Technological University1
Md Mainul IslamWestern Sydney University1
Mahmood H. NagrialWestern Sydney University1
Jamal RizkWestern Sydney University1
Ali HellanyWestern Sydney University1
Bashar Abdullah HamadNorthern Technical University1
A. Al DosariUnited Arab Emirates University1
Mohamed Shaker AlhammadiUnited Arab Emirates University1
Nasser AldarmakiUnited Arab Emirates University1
A. O. IdrisAfiliasi tidak diketahui1
A. N. AldarmakiUnited Arab Emirates University1
Basil HamedUnited Arab Emirates University1
Zeeshan Ahmad ArfeenIslamia University of Bahawalpur1
Ahmad Safawi MokhtarUniversity of Technology Malaysia1
Saleh Masoud Abdallah AltbawiUniversity of Technology Malaysia1
Rayan Hamza AlsisiIslamic University of Madinah1
Mehreen Kausar AzamUniversity of Sindh1
Nor Azwan Mohamed KamariNational University of Malaysia1
Ahmad Asrul IbrahimNational University of Malaysia1
Mohd Hairi Mohd ZamanNational University of Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Performance Comparison of Artificial Intelligence Techniques for Non-intrusive Electrical Load Monitoring</dc:title><dc:creator>Khairuddin Khalid</dc:creator><dc:creator>Azah Mohamed</dc:creator><dc:creator>Ramizi Mohamed</dc:creator><dc:creator>Hussain Shareef</dc:creator><dc:subject>non-intrusive load monitoring</dc:subject><dc:subject>load disaggregation</dc:subject><dc:subject>smart meters</dc:subject><dc:subject>extreme learning machine</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>support vector machine</dc:subject><dc:subject>commercial buildings</dc:subject><dc:subject>energy consumption monitoring</dc:subject><dc:description xml:lang="en">The increased awareness in reducing energy consumption and encouraging response from the use of smart meters have triggered the idea of non-intrusive load monitoring (NILM). The purpose of NILM is to obtain useful information about the usage of electrical appliances usually measured at the main entrance of electricity to obtain aggregate power signal by using a smart meter. The load operating states based on the on/off loads can be detected by analysing the aggregate power signals. This paper presents a comparative study for evaluating the performance of artificial intelligence techniques in classifying the type and operating states of three load types that are usually available in commercial buildings, such as fluorescent light, air-conditioner and personal computer. In this NILM study, experiments were carried out to collect information of the load usage pattern by using a commercial smart meter. From the power parameters captured by the smart meter, effective signal analysis has been done using the time time (TT)-transform to achieve accurate load disaggregation. Load feature selection is also considered by using three power parameters which are real power, reactive power and the TT-transform parameters. These three parameters are used as inputs for training the artificial intelligence techniques in classifying the type and operating states of the loads. The load classification results showed that the proposed extreme learning machine (ELM) technique has successfully achieved high accuracy and fast learning compared with artificial neural network and support vector machine. Based on validation results, ELM achieved the highest load classification with 100% accuracy for data sampled at 1 minute time interval.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2018-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v7i2.1190</dc:identifier><dc:identifier>10.11591/eei.v7i2.1190</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 7 No 2 (2018); 143-152</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1190/1988</dc:relation></oai_dc:dc>