Abstrak

The paper presents a comprehensive review carried out to identify the kinematic variables used in upper body rehabilitation assisted by robotic devices to assess the motor impairment of stroke patients and investigates the correlation between the kinematic variables and the clinical scales. Twenty-nine kinematic variables have been studied from twenty-eight articles involving 738 subacute or chronic stroke patients. The movement of speed, distance, accuracy, peak speed, peak speed ratio and number of peak speed were found to be the most frequently used kinematic variables in the aforementioned studies. Seven out of twenty-eight included articles examined the correlations between the kinematic variables used with the clinical scales. Some kinematic variables seem to have a strong correlation with the clinical scales but most of the kinematic variables have a moderate or weak correlation value. The important kinematic variables for evaluating the motor performance during rehabilitation assisted by robotic devices have been discussed. A suitable selected set of kinematic variables and clinical scale can potentially enhance the correlation value, at the same time can predict the clinical score evaluated by physiotherapist during the rehabilitation program with a high degree of accuracy.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 39 tautan kepenulisan bersama · 29 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • University of Brawijaya
  • University of Technology Malaysia
  • Coventry University
  • Institute of Technology Sligo
  • London Metropolitan University
  • Mercu Buana University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammad Saiful HuqLondon Metropolitan University2
Mohammed AhmedTun Hussein Onn University of Malaysia1
Dirman HanafiTun Hussein Onn University of Malaysia1
Kamal Khairi KamaruddinTun Hussein Onn University of Malaysia1
Yudhi GunardiMercu Buana University1
Abu Ubaidah ShamsudinTun Hussein Onn University of Malaysia1
Mohd Khairul Ikhwan AhmadTun Hussein Onn University of Malaysia1
Zubair Adil SoomroTun Hussein Onn University of Malaysia1
Ruzairi Abdul RahimUniversity of Technology Malaysia1
Muhammad Aziz MuslimUniversity of Brawijaya1
Mochammad RusliUniversity of Brawijaya1
Achnafian Rafif ZufaryansyahUniversity of Brawijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Kinematic variables for upper limb rehabilitation robot and correlations with clinical scales: A review</dc:title><dc:creator>Sulaiman Mazlan</dc:creator><dc:creator>Hisyam Bin Abdul Rahman</dc:creator><dc:creator>Che Fai Yeong</dc:creator><dc:creator>B. S. K. K. Ibrahim</dc:creator><dc:creator>Muhamad Saif Huq</dc:creator><dc:subject>upper limb rehabilitation</dc:subject><dc:subject>rehabilitation robots</dc:subject><dc:subject>kinematic parameters</dc:subject><dc:subject>stroke</dc:subject><dc:subject>motor impairment assessment</dc:subject><dc:subject>clinical scales</dc:subject><dc:subject>movement speed</dc:subject><dc:subject>motor performance</dc:subject><dc:subject>subacute stroke</dc:subject><dc:subject>chronic stroke</dc:subject><dc:subject>physiotherapy</dc:subject><dc:description xml:lang="en">The paper presents a comprehensive review carried out to identify the kinematic variables used in upper body rehabilitation assisted by robotic devices to assess the motor impairment of stroke patients and investigates the correlation between the kinematic variables and the clinical scales. Twenty-nine kinematic variables have been studied from twenty-eight articles involving 738 subacute or chronic stroke patients. The movement of speed, distance, accuracy, peak speed, peak speed ratio and number of peak speed were found to be the most frequently used kinematic variables in the aforementioned studies. Seven out of twenty-eight included articles examined the correlations between the kinematic variables used with the clinical scales. Some kinematic variables seem to have a strong correlation with the clinical scales but most of the kinematic variables have a moderate or weak correlation value. The important kinematic variables for evaluating the motor performance during rehabilitation assisted by robotic devices have been discussed. A suitable selected set of kinematic variables and clinical scale can potentially enhance the correlation value, at the same time can predict the clinical score evaluated by physiotherapist during the rehabilitation program with a high degree of accuracy.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v9i1.1856</dc:identifier><dc:identifier>10.11591/eei.v9i1.1856</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 75-82</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>