Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Corona fault detection in switchgear with extreme learning machine

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 2 (2020)

DOI
10.11591/eei.v9i2.2058
ISSN
2089-3191, 2302-9285
Terbit
2020-03-23
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Switchgear is a very important component in a power distribution line. Failure in a switchgear can lead to catastrophic danger and losses. In this research, a fault detection system is proposed with the implementation of Extreme Learning Machine (ELM). This algorithm is capable to identify faults in a switchgear by analyzing the sound wave generated. Experiments are carried out to investigate the performance of the developed algorithm in identifying Corona faults in switchgears. The performances are analyzed in time and frequency domains, respectively. In time domain analysis, the results show 90.63%, 87.5%, and 87.5% of success rates in differentiating the Corona and non-Corona cases in training, validation and testing phases respectively. In frequency domain analysis, the results show 89.84%, 83.33%, and 87.5% success rates in training, validation and testing phases respectively. It can thus be concluded that the developed algorithm performed well in identifying Corona faults in switchgears.

Kata kunci

Jaringan kolaborasi para penulis

19 penulis · 70 tautan kepenulisan bersama · 34 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Tenaga Nasional
  • Politeknik Negeri Medan
  • TNB Research (Malaysia)
  • Korea Institute of Science and Technology
  • International Islamic University Malaysia
  • Universitas Sumatera Utara
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Jian Ding TanUniversiti Tenaga Nasional1
Chong Kok HenUniversiti Tenaga Nasional1
Ying Ying KoayUniversiti Tenaga Nasional1
Siaw Paw KohUniversiti Tenaga Nasional1
Janaka Bandara EkanayakeUniversiti Tenaga Nasional1
Taufik Bin NurAfiliasi tidak diketahui1
Abdi Hanra SebayangPoliteknik Negeri Medan1
Arridina Susan SilitongaPoliteknik Negeri Medan1
Jassinnee MilanoUniversiti Tenaga Nasional1
Mei Yin OngUniversiti Tenaga Nasional1
Ahmad MasudiKorea Institute of Science and Technology1
Masjuki Haji HassanInternational Islamic University Malaysia1
Bela NurulitaUniversitas Sumatera Utara1
Adri Rakha SebayangPoliteknik Negeri Medan1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Corona fault detection in switchgear with extreme learning machine</dc:title><dc:creator>Sanuri Ishak</dc:creator><dc:creator>Siaw-Paw Koh</dc:creator><dc:creator>Jian-Ding Tan</dc:creator><dc:creator>Sieh-Kiong Tiong</dc:creator><dc:creator>Chai-Phing Chen</dc:creator><dc:subject>switchgear</dc:subject><dc:subject>extreme learning machine</dc:subject><dc:subject>acoustic fault diagnosis</dc:subject><dc:subject>distribution lines</dc:subject><dc:subject>frequency domain analysis</dc:subject><dc:subject>time-domain analysis</dc:subject><dc:description xml:lang="en">Switchgear is a very important component in a power distribution line. Failure in a switchgear can lead to catastrophic danger and losses. In this research, a fault detection system is proposed with the implementation of Extreme Learning Machine (ELM). This algorithm is capable to identify faults in a switchgear by analyzing the sound wave generated. Experiments are carried out to investigate the performance of the developed algorithm in identifying Corona faults in switchgears. The performances are analyzed in time and frequency domains, respectively. In time domain analysis, the results show 90.63%, 87.5%, and 87.5% of success rates in differentiating the Corona and non-Corona cases in training, validation and testing phases respectively. In frequency domain analysis, the results show 89.84%, 83.33%, and 87.5% success rates in training, validation and testing phases respectively. It can thus be concluded that the developed algorithm performed well in identifying Corona faults in switchgears.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-03-23</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i2.2058</dc:identifier><dc:identifier>10.11591/eei.v9i2.2058</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 2 (2020)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2058/1343</dc:relation></oai_dc:dc>