Performance comparison of distributed generation installation arrangement in transmission system for loss control

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 1 (2019) · hlm. 39–45

DOI
10.11591/eei.v8i1.1443
ISSN
2089-3191, 2302-9285
Terbit
2019-03-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Placing Distributed Generation (DG) into a power network should be planned wisely. In this paper, the comparison of having different installation arrangement of real-power DGs in transmission system for loss control is presented. Immune-brainstorm-evolutionary programme (IBSEP) was chosen as the optimization technique. It is found that optimizing fixed-size DGs locations gives the highest loss reduction percentage. Apart from that, scattered small-sized DGs throughout a network minimizes transmission loss more than allocating one biger-sized DG at a location.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 106 tautan kepenulisan bersama · 46 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • Universiti Tenaga Nasional
  • UCSI University
  • National University of Malaysia
  • University Ferhat Abbas of Setif
  • University of Brawijaya
  • HELP University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad Murtadha OthmanUniversiti Teknologi MARA11
Shahrizal JelaniUCSI University8
Nor Azura Md GhaniUniversiti Teknologi MARA5
Hadi SuyonoUniversity of Brawijaya5
Zulkiffli Abdul HamidUniversiti Teknologi MARA4
A.V.Senthil KumarAfiliasi tidak diketahui4
Muhamad Faliq Mohamad NazerUCSI University4
Rini Nur HasanahUniversity of Brawijaya3
Mohammad Lutfi OthmanUniversiti Putra Malaysia3
Saiful Izwan SulimanUniversiti Teknologi MARA3
Sulaiman ShaariUniversiti Teknologi MARA3
Saadi Bin Ahmad KamaruddinHELP University2
Nor Azwan Mohamed KamariNational University of Malaysia2
Naeem M. S. HannoonUniversiti Teknologi MARA2
Nabil M. HidayatUniversiti Teknologi MARA2
Ameerul A. J. JemanUniversiti Teknologi MARA2
Mohamed M. H. AdamUniversiti Teknologi MARA2
Muhammad Firdaus ShaariUniversiti Teknologi MARA2
Farah Adilah JamaludinUCSI University2
Chong Kok HenUniversiti Tenaga Nasional2
Norazlan HashimUniversiti Teknologi MARA1
Nik Fasdi Nik IsmailUniversiti Teknologi MARA1
Dalina JohariUniversiti Teknologi MARA1
Azhan Ab RahmanUniversiti Teknikal Malaysia Melaka1
Ramzi KouadriUniversity Ferhat Abbas of Setif1
Linda SlimaniUniversity Ferhat Abbas of Setif1
Tarek BouktirUniversity Ferhat Abbas of Setif1
Hazrita Ab RahimHELP University1
Ammar Yasier AzmanUniversiti Teknologi MARA1
Nofri Yenita DahlanUniversiti Teknologi MARA1
Wan Nazirah Wan Md AdnanUniversity of Selangor1
Ahmad Asrul IbrahimNational University of Malaysia1
Syahirah Abd HalimNational University of Malaysia1
K. KamilUniversiti Tenaga Nasional1
Huzaifa HashimUniversiti Tenaga Nasional1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Performance comparison of distributed generation installation arrangement in transmission system for loss control</dc:title><dc:creator>Sharifah Azwa Shaaya</dc:creator><dc:creator>Ismail Musirin</dc:creator><dc:creator>Shahril Irwan Sulaiman</dc:creator><dc:creator>Mohd Helmi Mansor</dc:creator><dc:creator>Sharifah Azma Syed Mustaffa</dc:creator><dc:subject>distributed generation</dc:subject><dc:subject>distributed generation placement</dc:subject><dc:subject>transmission loss reduction</dc:subject><dc:subject>DG sizing</dc:subject><dc:subject>power distribution planning</dc:subject><dc:subject>loss control</dc:subject><dc:description xml:lang="en">Placing Distributed Generation (DG) into a power network should be planned wisely. In this paper, the comparison of having different installation arrangement of real-power DGs in transmission system for loss control is presented. Immune-brainstorm-evolutionary programme (IBSEP) was chosen as the optimization technique. It is found that optimizing fixed-size DGs locations gives the highest loss reduction percentage. Apart from that, scattered small-sized DGs throughout a network minimizes transmission loss more than allocating one biger-sized DG at a location.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i1.1443</dc:identifier><dc:identifier>10.11591/eei.v8i1.1443</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 1 (2019); 39-45</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/1443/1105</dc:relation></oai_dc:dc>