Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Experimental simulation analysis for single phase transformer tests

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 3 (2020) · hlm. 862–869

DOI
10.11591/eei.v9i3.1710
ISSN
2089-3191, 2302-9285
Terbit
2020-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Transformer is one of main components in electrical power system which role to increase or reduce voltage. Characteristics of transformer would be vital to ensure the voltage is fully transferred. A single-phase transformer is a type of power transformer that utilizes single-phase alternating current, meaning the transformer relies on a voltage cycle that operates in a unified time phase. This article describes a workflow executed with Mat lab simulation and practical measurements for single-phase power transformer, no-load, short-circuit test and load test are achieved in this work. The test procedures are implemented on areal transformer (terco-type) which has a specification (1 KVA, 220/110 V, 50 Hz). Finally, the simulation results are appeared a proximately seminar from the practical results. The results indicated that the the technique and manner which presented in the current study can be depended as a miniproject in electrical technology mater for undergraduate studies.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 20 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed Ahmed IbrahimNorthern Technical University2
Safwan Assaf HamoodiNorthern Technical University2
Ali Salah AlhfidhNorthern Technical University1
Farah Isam HameedNorthern Technical University1
Fawwaz Jassim MohammedNorthern Technical University1
Bashar M. SalihAfiliasi tidak diketahui1
Ghanim M.HaydarAfiliasi tidak diketahui1
Bashar Mohammed SalihNorthern Technical University1
Ahmed A. Abdullah Al-KarakchiNorthern Technical University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Experimental simulation analysis for single phase transformer tests</dc:title><dc:creator>Ali Nathem Hamoodi</dc:creator><dc:creator>Bashar A. Hammad</dc:creator><dc:creator>Fawaz Sultan Abdullah</dc:creator><dc:subject>single-phase transformer</dc:subject><dc:subject>transformer testing</dc:subject><dc:subject>no-load test</dc:subject><dc:subject>short-circuit test</dc:subject><dc:subject>load testing</dc:subject><dc:subject>MATLAB simulation</dc:subject><dc:subject>power transformers</dc:subject><dc:subject>undergraduate electrical engineering education</dc:subject><dc:description xml:lang="en">Transformer is one of main components in electrical power system which role to increase or reduce voltage. Characteristics of transformer would be vital to ensure the voltage is fully transferred. A single-phase transformer is a type of power transformer that utilizes single-phase alternating current, meaning the transformer relies on a voltage cycle that operates in a unified time phase. This article describes a workflow executed with Mat lab simulation and practical measurements for single-phase power transformer, no-load, short-circuit test and load test are achieved in this work. The test procedures are implemented on areal transformer (terco-type) which has a specification (1 KVA, 220/110 V, 50 Hz). Finally, the simulation results are appeared a proximately seminar from the practical results. The results indicated that the the technique and manner which presented in the current study can be depended as a miniproject in electrical technology mater for undergraduate studies.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i3.1710</dc:identifier><dc:identifier>10.11591/eei.v9i3.1710</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 3 (2020); 862-869</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1710/1408</dc:relation></oai_dc:dc>