Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Machinery signal separation using non-negative matrix factorization with real mixing

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 4 (2020) · hlm. 1468–1476

DOI
10.11591/eei.v9i4.1956
ISSN
2089-3191, 2302-9285
Terbit
2020-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

A big challenge in detecting damage occurs when the sound of a machine mixes with the sound of another machine. This paper proposes the separation of mixed acoustic signals using Non-negative Matrix Factorization (NMF) method for fault diagnosis. The NMF method is an effective solution for finding hidden parameters when the number of observations obtained by the sensor is less than the number of sources. The real mixing process is done by placing two microphones in front of the machine. Two microphones will be used as sensors to capture a mixture of four machinery signals. Performance testing of signal separation is done by comparing baseline signals with estimated signals through the mean log spectral distance (LSD) and the mean square error (MSE). The smallest spectral distance between the estimated signal and the baseline signal is found in Ŝ2 with an average LSD of 1.26. The estimated signal Ŝ2 is the closest to the baseline signal with MSE of 1.15 x 10-2. The pattern of bearing damage in the male screw compressor can be identified from the spectrum of estimated signal through harmonic frequencies as in the estimated signal Ŝ3 which is seen at 11x fundamental frequency, 12x fundamental frequency, 15x fundamental frequency, and 16x fundamental frequency.

Kata kunci

Jaringan kolaborasi para penulis

32 penulis · 118 tautan kepenulisan bersama · 67 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Universitas Pertamina
  • Universitas Internasional Semen Indonesia
  • Universitas Sebelas Maret
  • Universiti Teknologi Petronas
  • Politeknik Elektronika Negeri Surabaya
  • National Research and Innovation Agency
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Iva Yenis SeptiarivaUniversitas Sebelas Maret2
Niswatun FariaUniversitas Internasional Semen Indonesia2
Jun Wei LimUniversiti Teknologi Petronas2
I Wayan Koko SuryawanUniversitas Pertamina2
Bagus Tris AtmajaInstitut Teknologi Sepuluh Nopember1
Anas Siti AisyahInstitut Teknologi Sepuluh Nopember1
Mega Muitiara SariAfiliasi tidak diketahui1
Eva Nur FauziahUniversitas Pertamina1
Kuntum Khoiro UmmatinUniversitas Internasional Semen Indonesia1
Haniah MahmudahInstitut Teknologi Sepuluh Nopember1
Syamsul ArifinPoliteknik Elektronika Negeri Surabaya1
Catur Arif PrastyantoInstitut Teknologi Sepuluh Nopember1
Sapta SuhardonoUniversitas Sebelas Maret1
Kuntum Khoiro UmmatinUniversitas Internasional Semen Indonesia1
Ariyanti SarwonoUniversitas Pertamina1
Mega Mutiara SariUniversitas Pertamina1
Nurulbaiti Listyendah ZahraUniversitas Pertamina1
Fatimah Dinan QonitanUniversitas Pertamina1
Pratiwi Claudia GainaUniversitas Pertamina1
Mat Syai’inInstitut Teknologi Sepuluh Nopember1
Syamsul ArifinInstitut Teknologi Sepuluh Nopember1
Syamsiar KautsarInstitut Teknologi Sepuluh Nopember1
Edi KurniawanNational Research and Innovation Agency1
Akif RahmatillahInstitut Teknologi Sepuluh Nopember1
SuyantoInstitut Teknologi Sepuluh Nopember1
Sri Nastiti Nugrahani EkasiwiInstitut Teknologi Sepuluh Nopember1
Thomas Ari KristiantoInstitut Teknologi Sepuluh Nopember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Machinery signal separation using non-negative matrix factorization with real mixing</dc:title><dc:creator>Anindita Adikaputri Vinaya</dc:creator><dc:creator>Sefri Yulianto</dc:creator><dc:creator>Qurrotin Ayunina Maulida Okta Arifianti</dc:creator><dc:creator>Dhany Arifianto</dc:creator><dc:creator>Aulia Siti Aisjah</dc:creator><dc:subject>non-negative matrix factorization</dc:subject><dc:subject>blind source separation</dc:subject><dc:subject>bearing fault diagnosis</dc:subject><dc:subject>screw compressor</dc:subject><dc:subject>acoustic signal analysis</dc:subject><dc:subject>spectral distance</dc:subject><dc:subject>harmonics</dc:subject><dc:subject>damage detection</dc:subject><dc:description xml:lang="en">A big challenge in detecting damage occurs when the sound of a machine mixes with the sound of another machine. This paper proposes the separation of mixed acoustic signals using Non-negative Matrix Factorization (NMF) method for fault diagnosis. The NMF method is an effective solution for finding hidden parameters when the number of observations obtained by the sensor is less than the number of sources. The real mixing process is done by placing two microphones in front of the machine. Two microphones will be used as sensors to capture a mixture of four machinery signals. Performance testing of signal separation is done by comparing baseline signals with estimated signals through the mean log spectral distance (LSD) and the mean square error (MSE). The smallest spectral distance between the estimated signal and the baseline signal is found in Ŝ2 with an average LSD of 1.26. The estimated signal Ŝ2 is the closest to the baseline signal with MSE of 1.15 x 10-2. The pattern of bearing damage in the male screw compressor can be identified from the spectrum of estimated signal through harmonic frequencies as in the estimated signal Ŝ3 which is seen at 11x fundamental frequency, 12x fundamental frequency, 15x fundamental frequency, and 16x fundamental frequency.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i4.1956</dc:identifier><dc:identifier>10.11591/eei.v9i4.1956</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 4 (2020); 1468-1476</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1956/1511</dc:relation></oai_dc:dc>