Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Normal operation and reverse action of on-load tap changing transformer with its effect on voltage stability

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 2 (2023) · hlm. 650–658

DOI
10.11591/eei.v12i2.4556
ISSN
2089-3191, 2302-9285
Terbit
2023-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

As electrical grids have expanded significantly, so too has the load on network buses. This, however, causes voltage drops to occur at the load side of the grid. A voltage drop causes a system to become unstable, increases its power loss, and reduces the amount of power that it transfers before finally leading to a collapse. An on-load tap changing (OLTC) transformer can be used to prevent the negative effects of an increased load by restoring the load voltage to its base value when sudden disturbances occur in the source. However, incorrect OLTC placement can cause the system to become unstable and cause collapse. This is referred to as the reverse action phenomenon of an OLTC. Therefore, this present study examined improving the ability of an OLTC to increase system stability and prevent collapse. A simple radial power distribution system was modelled in MATLAB. The results indicate that the proposed model can increase system stability and prevent collapse.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 5 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Mosul
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hiba Nadhim A. Al-KaoazUniversity of Mosul1
Ziyad M. T. SallehUniversity of Mosul1
Hasan Adnan MohammedUniversity of Mosul1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Normal operation and reverse action of on-load tap changing transformer with its effect on voltage stability</dc:title><dc:creator>Sinan Alkahdely</dc:creator><dc:creator>Ahmed Nasser B. Alsammak</dc:creator><dc:subject>on-load tap changing transformers</dc:subject><dc:subject>voltage stability</dc:subject><dc:subject>voltage drop</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>power losses</dc:subject><dc:subject>voltage collapse prevention</dc:subject><dc:subject>transformer tap settings</dc:subject><dc:description xml:lang="en">As electrical grids have expanded significantly, so too has the load on network buses. This, however, causes voltage drops to occur at the load side of the grid. A voltage drop causes a system to become unstable, increases its power loss, and reduces the amount of power that it transfers before finally leading to a collapse. An on-load tap changing (OLTC) transformer can be used to prevent the negative effects of an increased load by restoring the load voltage to its base value when sudden disturbances occur in the source. However, incorrect OLTC placement can cause the system to become unstable and cause collapse. This is referred to as the reverse action phenomenon of an OLTC. Therefore, this present study examined improving the ability of an OLTC to increase system stability and prevent collapse. A simple radial power distribution system was modelled in MATLAB. The results indicate that the proposed model can increase system stability and prevent collapse.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i2.4556</dc:identifier><dc:identifier>10.11591/eei.v12i2.4556</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 2 (2023); 650-658</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4556/3128</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>