Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effect of repeated electrical breakdowns on mineral and natural ester insulating oils

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 6 (2021) · hlm. 2989–2996

DOI
10.11591/eei.v10i6.3258
ISSN
2089-3191, 2302-9285
Terbit
2021-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Transformer insulating oils are exposed to repeated electrical discharge or breakdowns inside power transformers. Durability tests are conducted to analyze the ability of oil to resist decomposition due to such high electrical stresses. With the increasing demand for alternative insulating oils for oil-immersed transformers, it is worthy to compare the performance of different types of insulating oils (conventional mineral-based insulating oil and natural ester-based insulating oil) under repeated electrical breakdown. In this paper, the AC breakdown voltage of different mineral-based and natural ester-based insulating oils is reported. Durability tests were conducted based on the AC breakdown voltage behavior of insulating oils after 50 electrical breakdown shots. The AC breakdown voltage of each insulating oil sample was assessed according to the ASTM D1816 standard test method. Based on the results, it can be concluded that the dissimilarity in chemical composition of the insulating oils has a significant effect on the AC breakdown voltage behavior of these oils under repeated electrical breakdowns.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 136 tautan kepenulisan bersama · 41 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Tun Hussein Onn University of Malaysia
  • Universiti Malaysia Perlis
  • University of Technology Malaysia
  • Universiti Sains Malaysia
  • Universiti Malaysia Kelantan
  • Universiti Tenaga Nasional
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nor Hidayah RahimUniversiti Teknikal Malaysia Melaka18
Norazhar B. Abu BakarUniversiti Teknikal Malaysia Melaka17
Muhammad Syahrani JohalUniversiti Teknikal Malaysia Melaka15
Hidayat ZainuddinUniversiti Teknikal Malaysia Melaka9
Mohamad Nazri Mohamad DinAfiliasi tidak diketahui9
Nur Farhana Mohd AzlanUniversiti Teknikal Malaysia Melaka6
Mohamad Nazri Mohamad DinAfiliasi tidak diketahui6
Syahrun Nizam Md Arshad HashimUniversiti Malaysia Perlis6
Mohd Safwan MohamadUniversiti Teknikal Malaysia Melaka4
Mohd Zamri Che WanikUniversiti Malaysia Kelantan3
Nur Izyan Husnina ZulkefliUniversiti Teknikal Malaysia Melaka3
Muhammad Asyraf ZainalAfiliasi tidak diketahui3
Muhamad Falihan BahariUniversiti Teknikal Malaysia Melaka3
Nor Asiah MuhamadUniversiti Sains Malaysia2
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia2
Muhammad Ilman Hakimi Chua AbdullahUniversiti Teknikal Malaysia Melaka2
Norsyabilah RidzuanUniversiti Teknikal Malaysia Melaka2
N. H. A. AzizUniversiti Teknikal Malaysia Melaka2
Nur Amirah OthmanUniversiti Teknikal Malaysia Melaka1
Aminuddin AmanUniversiti Teknikal Malaysia Melaka1
Sharin Abd GhaniAfiliasi tidak diketahui1
Ezreen Farina ShairUniversiti Teknikal Malaysia Melaka1
Nur Zawani SaharuddinUniversiti Teknikal Malaysia Melaka1
Amar Saufi NasirUniversiti Teknikal Malaysia Melaka1
Izham Zainal AbidinUniversiti Tenaga Nasional1
Rahisham Abd RahmanTun Hussein Onn University of Malaysia1
Mohd Fairouz Mohd YousofTun Hussein Onn University of Malaysia1
Nurul Farahwahida Md YasidTun Hussein Onn University of Malaysia1
Tole SutiknoUniversitas Ahmad Dahlan1
Auzani JidinUniversiti Teknikal Malaysia Melaka1
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka1
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka1
M. S. KamarudinTun Hussein Onn University of Malaysia1
Ayuamira ZahariUniversiti Teknikal Malaysia Melaka1
Nur Farhani AmboLimkokwing University of Creative Technology1
Jamaludin Mohd WariAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Effect of repeated electrical breakdowns on mineral and natural ester insulating oils</dc:title><dc:creator>Sharin Ab Ghani</dc:creator><dc:creator>Mohd Shahril Ahmad Khiar</dc:creator><dc:creator>Imran Sutan Chairul</dc:creator><dc:creator>Muhammad Imran Zamir</dc:creator><dc:subject>transformer oil</dc:subject><dc:subject>mineral oil</dc:subject><dc:subject>natural ester insulating oil</dc:subject><dc:subject>AC breakdown voltage</dc:subject><dc:subject>oil decomposition</dc:subject><dc:subject>oil-immersed transformers</dc:subject><dc:description xml:lang="en">Transformer insulating oils are exposed to repeated electrical discharge or breakdowns inside power transformers. Durability tests are conducted to analyze the ability of oil to resist decomposition due to such high electrical stresses. With the increasing demand for alternative insulating oils for oil-immersed transformers, it is worthy to compare the performance of different types of insulating oils (conventional mineral-based insulating oil and natural ester-based insulating oil) under repeated electrical breakdown. In this paper, the AC breakdown voltage of different mineral-based and natural ester-based insulating oils is reported. Durability tests were conducted based on the AC breakdown voltage behavior of insulating oils after 50 electrical breakdown shots. The AC breakdown voltage of each insulating oil sample was assessed according to the ASTM D1816 standard test method. Based on the results, it can be concluded that the dissimilarity in chemical composition of the insulating oils has a significant effect on the AC breakdown voltage behavior of these oils under repeated electrical breakdowns.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i6.3258</dc:identifier><dc:identifier>10.11591/eei.v10i6.3258</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 6 (2021); 2989-2996</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3258/2390</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>