Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A novel miniaturized radiometer front-end for early breast cancer detection using ultra-wideband flexible antenna

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 1 (2024) · hlm. 277–291

DOI
10.11591/eei.v13i1.5702
ISSN
2089-3191, 2302-9285
Terbit
2024-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This article introduces a new design of the front-end part of a passive and miniature radiometer, which has been developed to detect breast cancer at an early stage, by measuring temperature in deep mammary tissues. The design and simulation of each element of the microwave radiometer are carried out using computer simulation technology microwave (CST MWS) software. The proposed measurement system consists of a miniaturized ultra-wideband (UWB) flexible antenna operating in the S-band (2-4 GHz), a breast phantom, a low noise amplifier (LNA), a bandpass filter, and a radio frequency (RF) power detector. These components were combined with active circuits to build the front-end system using the co-simulation modules provided by the CST MWS. The method is based on the concept that the virtually created tumor increases the temperature inside the breast phantom, and to detect the abnormality, we applied the proposed radiometer front-end on breast phantom to measure the gain variation. The results demonstrated that the design of the proposed miniaturized radiometer has promising performance in terms of stability and gain variation, indeed, the difference in maximum gain |ΔGmax| measured between abnormal and healthy phantom is about 0.92 dB at 2.75 GHz. This indicates its potential for detecting breast tumors.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 15 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Lyon 1 Université
  • University of Hassan II Casablanca
  • Université Sultan Moulay Slimane
  • Chouaib Doukkali University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdelhamid ErrachidLyon 1 Université4
Mohamed MoutchouUniversity of Hassan II Casablanca2
Abdelouahad AchmamadMohammed V University2
Mounaim AqilUniversité Sultan Moulay Slimane1
Abdelali BelkhouMohammed V University1
Younes AbouelmahjoubChouaib Doukkali University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A novel miniaturized radiometer front-end for early breast cancer detection using ultra-wideband flexible antenna</dc:title><dc:creator>Achraf Elouerghi</dc:creator><dc:creator>Zakaryae Khomsi</dc:creator><dc:creator>Larbi Bellarbi</dc:creator><dc:creator>Atman Jbari</dc:creator><dc:subject>microwave radiometer</dc:subject><dc:subject>breast cancer early detection</dc:subject><dc:subject>ultra-wideband antenna</dc:subject><dc:subject>flexible antenna</dc:subject><dc:subject>S-band</dc:subject><dc:subject>breast phantom</dc:subject><dc:subject>low noise amplifier</dc:subject><dc:subject>bandpass filter</dc:subject><dc:subject>RF power detector</dc:subject><dc:subject>gain variation</dc:subject><dc:subject>co-simulation</dc:subject><dc:description xml:lang="en">This article introduces a new design of the front-end part of a passive and miniature radiometer, which has been developed to detect breast cancer at an early stage, by measuring temperature in deep mammary tissues. The design and simulation of each element of the microwave radiometer are carried out using computer simulation technology microwave (CST MWS) software. The proposed measurement system consists of a miniaturized ultra-wideband (UWB) flexible antenna operating in the S-band (2-4 GHz), a breast phantom, a low noise amplifier (LNA), a bandpass filter, and a radio frequency (RF) power detector. These components were combined with active circuits to build the front-end system using the co-simulation modules provided by the CST MWS. The method is based on the concept that the virtually created tumor increases the temperature inside the breast phantom, and to detect the abnormality, we applied the proposed radiometer front-end on breast phantom to measure the gain variation. The results demonstrated that the design of the proposed miniaturized radiometer has promising performance in terms of stability and gain variation, indeed, the difference in maximum gain |ΔGmax| measured between abnormal and healthy phantom is about 0.92 dB at 2.75 GHz. This indicates its potential for detecting breast tumors.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i1.5702</dc:identifier><dc:identifier>10.11591/eei.v13i1.5702</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 1 (2024); 277-291</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5702/3540</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>