Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

An extended sensor fault tolerant control method applied to three-phase induction motor drives

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 1 (2024) · hlm. 125–133

DOI
10.11591/eei.v13i1.5992
ISSN
2089-3191, 2302-9285
Terbit
2024-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This research presents a fault tolerant (FT) control method for three-phase induction motor drives (IMDs) against sensor failures in the operating process. In this paper, an IMD applied the field oriented (FO) control for the speed and torque control is used to study the operation under sensor fault conditions. A fault detection isolation function is integrated into the FO control loop as an intermediary component to evaluate the quality of the measured signals of the sensors and provide proper signals for speed control of the drive system. A combined method of a comparison algorithm and a third difference operator (TDO) is proposed for the fault diagnosis function to improve the sustainable operation of the drive. The reliability of the proposed method will be verified through the operation mechanism of the FT function corresponding to three sensor fault states and a random noise state in the simulation environment by MATLAB/Simulink software.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 41 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ton Duc Thang University
  • VSB - Technical University of Ostrava
  • Saigon University
  • Van Lang University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bach Hoang DinhTon Duc Thang University6
Pavel BrandštetterVSB - Technical University of Ostrava5
Sang Dang HoTon Duc Thang University5
Phuong Nhat PhamTon Duc Thang University4
Xuan Tien NguyenSaigon University2
Petr PalackýVSB - Technical University of Ostrava1
Martin KuchařVSB - Technical University of Ostrava1
Quang Sy VuVan Lang University1
Chau Si Thien DongTon Duc Thang University1
Hung Tan HuynhTon Duc Thang University1
Huy Xuan PhanAfiliasi tidak diketahui1
Tien Xuan NguyenSaigon University1
Nguyễn Duy PhươngSaigon University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">An extended sensor fault tolerant control method applied to three-phase induction motor drives</dc:title><dc:creator>Minh Chau Huu Nguyen</dc:creator><dc:creator>Cuong Dinh Tran</dc:creator><dc:subject>fault-tolerant control</dc:subject><dc:subject>sensor faults</dc:subject><dc:subject>three-phase induction motor drive</dc:subject><dc:subject>field-oriented control</dc:subject><dc:subject>fault detection and isolation</dc:subject><dc:subject>comparison algorithm</dc:subject><dc:subject>speed control</dc:subject><dc:subject>torque control</dc:subject><dc:description xml:lang="en">This research presents a fault tolerant (FT) control method for three-phase induction motor drives (IMDs) against sensor failures in the operating process. In this paper, an IMD applied the field oriented (FO) control for the speed and torque control is used to study the operation under sensor fault conditions. A fault detection isolation function is integrated into the FO control loop as an intermediary component to evaluate the quality of the measured signals of the sensors and provide proper signals for speed control of the drive system. A combined method of a comparison algorithm and a third difference operator (TDO) is proposed for the fault diagnosis function to improve the sustainable operation of the drive. The reliability of the proposed method will be verified through the operation mechanism of the FT function corresponding to three sensor fault states and a random noise state in the simulation environment by MATLAB/Simulink software.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i1.5992</dc:identifier><dc:identifier>10.11591/eei.v13i1.5992</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 1 (2024); 125-133</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5992/3523</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>