Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Stability analysis of power system under n-1 contingency condition

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 4 (2024) · hlm. 2940–2950

DOI
10.11591/eei.v13i4.6133
ISSN
2089-3191, 2302-9285
Terbit
2024-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Several voltage stability indices (VSIs) have been developed to assess the potential for voltage collapse. However, certain indexes are computationally costly. Meanwhile, some have been noted to underperform across various conditions. This work proposes a novel line index called the super voltage stability index (SVSI) to calculate the system's voltage stability margin (VSM). The suggested approach is based on the transmission system's two bus systems. The reactive power loss and N-1 contingency conditions to voltage sensitivity is a unique calculation approach used in this study to identify voltage instability. Day to day, the demand for electric power is being increased due to incessant increments in technology and population growth. Therefore, the power system networks are under pressure. The operational conditions of transmission system networks are affected at this point, which may result in voltage collapse. Regular monitoring of power supply is essential to avert voltage collapse. The effectiveness of the suggested index has been assessed using the IEEE 5 and 30-bus systems across diverse operating scenarios, including variations in active and reactive power loading as well as single line losses. The findings indicate that SVSI provides a more reliable indication of the proximity to voltage collapse when compared to conventional line VSIs.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 5 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vellore Institute of Technology University
  • JSPM University
  • PES University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Chethan Hiremarali RamalingegowdaVellore Institute of Technology University3
Pujari Harish KumarJSPM University1
K. M. Mahesh KumarPES University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Stability analysis of power system under n-1 contingency condition</dc:title><dc:creator>Guru Mohan Baleboina</dc:creator><dc:creator>R. Mageshvaran</dc:creator><dc:subject>voltage stability</dc:subject><dc:subject>N-1 contingency</dc:subject><dc:subject>voltage stability margin</dc:subject><dc:subject>voltage collapse</dc:subject><dc:subject>voltage stability index</dc:subject><dc:subject>reactive power loss</dc:subject><dc:subject>voltage sensitivity</dc:subject><dc:subject>transmission systems</dc:subject><dc:subject>IEEE 5-bus system</dc:subject><dc:subject>IEEE 30-bus system</dc:subject><dc:description xml:lang="en">Several voltage stability indices (VSIs) have been developed to assess the potential for voltage collapse. However, certain indexes are computationally costly. Meanwhile, some have been noted to underperform across various conditions. This work proposes a novel line index called the super voltage stability index (SVSI) to calculate the system's voltage stability margin (VSM). The suggested approach is based on the transmission system's two bus systems. The reactive power loss and N-1 contingency conditions to voltage sensitivity is a unique calculation approach used in this study to identify voltage instability. Day to day, the demand for electric power is being increased due to incessant increments in technology and population growth. Therefore, the power system networks are under pressure. The operational conditions of transmission system networks are affected at this point, which may result in voltage collapse. Regular monitoring of power supply is essential to avert voltage collapse. The effectiveness of the suggested index has been assessed using the IEEE 5 and 30-bus systems across diverse operating scenarios, including variations in active and reactive power loading as well as single line losses. The findings indicate that SVSI provides a more reliable indication of the proximity to voltage collapse when compared to conventional line VSIs.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i4.6133</dc:identifier><dc:identifier>10.11591/eei.v13i4.6133</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 4 (2024); 2940-2950</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6133/3838</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>