Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Content Cytotoxicity Studies of Colorectal Carcinoma Cells Using Printed Impedance Sensors

Bulletin of Electrical Engineering and Informatics · Vol. 6 No. 4 (2017) · hlm. 317–326

DOI
10.11591/eei.v6i4.851
ISSN
2089-3191, 2302-9285
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Monitoring the effectiveness of drugs on cancer cells is crucial for chemotherapeutics studies. In-vitro cell-based biosensors can be used as an alternative for characteristic studies of cells’ response to drugs. Cell-based sensors provide real-time measurements and require smaller sample volumes compared to conventional T-flask measurement methods. This paper presents a biosensor that detects in real-time, impedance variations of human colon cancer, HCT-116 cells when treated with anti-cancer agent, 5-Fluorouracil (5-FU). Two different extracellular matrix (ECM); polyaniline and gelatin were tested and evaluated in terms of attachment quality. Polyaniline was found to provide the best attachment for HCT-116 cells and was used for cytotoxicity studies. Cytokinetic behavior indicated that 5-FU inhibited HCT-116 cells at IC50 of 6.8 µg/mL. Trypan blue exclusion method for testing cell viability was used to validate the impedance measurements, where the cancer cell concentrations were reduced to ~35% when treated with 2.5 µg/mL, and 50% when treated with 6.8 µg/mL. The results generated by the microfabricated impedance biosensor are comparable to the Trypan blue method since both gave similar cell growth trend. It can be concluded that the impedance biosensor has potential to be used as an alternative method in drug testing applications.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 92 tautan kepenulisan bersama · 17 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • International Islamic University Malaysia
  • City College of New York
  • Jabil (United States)
  • National Institutes of Health
  • Yogyakarta State University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rosminazuin Ab RahimInternational Islamic University Malaysia2
Muhammad Irsyad SuhaimiJabil (United States)2
Zambri SamsudinAfiliasi tidak diketahui2
Teddy Surya GunawanInternational Islamic University Malaysia1
Fatchul ArifinYogyakarta State University1
Zainihariyati Mohd ZainAfiliasi tidak diketahui1
Faisal Ahmed AssaigInternational Islamic University Malaysia1
Rozainanee Mohd ZainNational Institutes of Health1
Nur Hanisah AzmiInternational Islamic University Malaysia1
Lim Lai MingAfiliasi tidak diketahui1
Aliza Aini Md RalibInternational Islamic University Malaysia1
Muhammad Farhan Affendi Mohamad YunosInternational Islamic University Malaysia1
Ahmad Anwar ZainuddinInternational Islamic University Malaysia1
Sheroz KhanInternational Islamic University Malaysia1
Muhammad Farhan Affendi bin YunosInternational Islamic University Malaysia1
Muhamad Aiman NazriInternational Islamic University Malaysia1
Lai Ming LimAfiliasi tidak diketahui1
Mohd Yusof Tura AliAfiliasi tidak diketahui1
Idris MansorAfiliasi tidak diketahui1
Raihan OthmanInternational Islamic University Malaysia1
Shahrul Razi MeskonInternational Islamic University Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Content Cytotoxicity Studies of Colorectal Carcinoma Cells Using Printed Impedance Sensors</dc:title><dc:creator>Anis Nurashikin Nordin</dc:creator><dc:creator>Irmanisha Ibrahim</dc:creator><dc:creator>Ahmad Fairuzabadi Mohd Mansor</dc:creator><dc:creator>Yumi Zuhanis Has-Yun Hashim</dc:creator><dc:creator>Ioana Voiculescu</dc:creator><dc:subject>impedance biosensor</dc:subject><dc:subject>printed sensors</dc:subject><dc:subject>colorectal cancer</dc:subject><dc:subject>HCT116 cells</dc:subject><dc:subject>5-fluorouracil</dc:subject><dc:subject>cytotoxicity</dc:subject><dc:subject>cell viability</dc:subject><dc:subject>polyaniline</dc:subject><dc:subject>gelatin</dc:subject><dc:subject>extracellular matrix</dc:subject><dc:subject>cell attachment</dc:subject><dc:subject>drug testing</dc:subject><dc:subject>real-time cell monitoring</dc:subject><dc:description xml:lang="en">Monitoring the effectiveness of drugs on cancer cells is crucial for chemotherapeutics studies. In-vitro cell-based biosensors can be used as an alternative for characteristic studies of cells’ response to drugs. Cell-based sensors provide real-time measurements and require smaller sample volumes compared to conventional T-flask measurement methods. This paper presents a biosensor that detects in real-time, impedance variations of human colon cancer, HCT-116 cells when treated with anti-cancer agent, 5-Fluorouracil (5-FU). Two different extracellular matrix (ECM); polyaniline and gelatin were tested and evaluated in terms of attachment quality. Polyaniline was found to provide the best attachment for HCT-116 cells and was used for cytotoxicity studies. Cytokinetic behavior indicated that 5-FU inhibited HCT-116 cells at IC50 of 6.8 µg/mL. Trypan blue exclusion method for testing cell viability was used to validate the impedance measurements, where the cancer cell concentrations were reduced to ~35% when treated with 2.5 µg/mL, and 50% when treated with 6.8 µg/mL. The results generated by the microfabricated impedance biosensor are comparable to the Trypan blue method since both gave similar cell growth trend. It can be concluded that the impedance biosensor has potential to be used as an alternative method in drug testing applications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v6i4.851</dc:identifier><dc:identifier>10.11591/eei.v6i4.851</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 6 No 4 (2017); 317-326</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/851/975</dc:relation></oai_dc:dc>