Energy management strategy with smart building control system to reduction electrical load using ANN

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3188–3200

DOI
10.11591/eei.v11i6.4087
ISSN
2089-3191, 2302-9285
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Buildings have long been large energy consumers, and inadequate control of heating, ventilation, and air conditioning kinds of variable refrigeration flow (HVAC-VRF) and lighting systems. To reduce energy consumption by using a smart building control system (SBCS) in a building was created using occupant control, daylight sensors, weather condition variations, load consumed, and changes in solar power. The model was tested using MATLAB/Simulink, and it was then utilized to investigate the impact of an integrated system on energy usage based on two scenarios. The first scenario was tested in a simulation of building occupant behavior, meteorological variables, daylight sensors, temperature, and load control. This resulted in energy savings for the HVAC system (23% on summer days and 16% on winter days), and lighting system energy savings (22% on summer days and 15% on winter days). In the second scenario, the building was tested to integrate PV system power with load consumption by using the artificial neural network (ANN) algorithm to manage building load consumption by PV, grid, and diesel generator. As a result, the energy savings were 56% on a summer day and 65% on a winter day of the combined energy utilized by the HVAC and lights.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology - Iraq
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hussein Hadi Abdul-Wahid Al-SadooniUniversity of Technology - Iraq1
Luay G. IbrahimUniversity of Technology - Iraq1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Energy management strategy with smart building control system to reduction electrical load using ANN</dc:title><dc:creator>Bareq Musaab Jalal</dc:creator><dc:creator>Rashid H. Al-Rubayi</dc:creator><dc:subject>building energy management</dc:subject><dc:subject>HVAC load reduction</dc:subject><dc:subject>lighting energy savings</dc:subject><dc:subject>occupant behavior</dc:subject><dc:subject>daylight sensors</dc:subject><dc:subject>photovoltaic integration</dc:subject><dc:subject>building energy consumption</dc:subject><dc:description xml:lang="en">Buildings have long been large energy consumers, and inadequate control of heating, ventilation, and air conditioning kinds of variable refrigeration flow (HVAC-VRF) and lighting systems. To reduce energy consumption by using a smart building control system (SBCS) in a building was created using occupant control, daylight sensors, weather condition variations, load consumed, and changes in solar power. The model was tested using MATLAB/Simulink, and it was then utilized to investigate the impact of an integrated system on energy usage based on two scenarios. The first scenario was tested in a simulation of building occupant behavior, meteorological variables, daylight sensors, temperature, and load control. This resulted in energy savings for the HVAC system (23% on summer days and 16% on winter days), and lighting system energy savings (22% on summer days and 15% on winter days). In the second scenario, the building was tested to integrate PV system power with load consumption by using the artificial neural network (ANN) algorithm to manage building load consumption by PV, grid, and diesel generator. As a result, the energy savings were 56% on a summer day and 65% on a winter day of the combined energy utilized by the HVAC and lights.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4087</dc:identifier><dc:identifier>10.11591/eei.v11i6.4087</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3188-3200</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4087/2988</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>