Efficiency and performance ratio of photovoltaics on a 50 kWp Universitas Pamulang Viktor rooftop solar power plant
Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 1 (2024) · hlm. 50–57
ISSN 2089-3191, 2302-9285
Terbit 2024-02-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
To overcome the fossil energy crisis due to the increasing need for electrical energy, new renewable energy sources are needed. Due to technological developments in the fields of transportation, industry, household, and commercial use. Indonesia’s geography has the potential to apply new renewable energy, more specifically photovoltaic (PV). However, it is greatly influenced by environmental factors such as solar radiation, voltage, which have an impact on the output power efficiency and performance. So, it is necessary to test both measurements and calculations to see the optimization of output power and PV efficiency. From previous research, it has not been carried out, especially in the experimental method Universitas Pamulang: measurement and empirical and for a sufficiently high capacity with the aim of optimal output power. Methods of measuring sunlight intensity, voltage and current, the calculation of converting sunlight intensity to solar constellation, power, efficiency, and performance ratio (PR). The average value being 721 W/m2 an efficiency value of 19.9% and a value PR is obtained of 0.967 or 96.7% is still realistic. So that the system is declared optimal.
Jaringan kolaborasi para penulis
11 penulis ·
23 tautan kepenulisan bersama
· 8 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Pamulang Universiti Malaysia Terengganu National Nuclear Energy Agency of Indonesia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Efficiency and performance ratio of photovoltaics on a 50 kWp Universitas Pamulang Viktor rooftop solar power plant</dc:title><dc:creator>Ojak Abdul Rozak</dc:creator><dc:creator>Aripin Triyanto</dc:creator><dc:creator>Heri Kusnadi</dc:creator><dc:subject>solar cell efficiency</dc:subject><dc:subject>performance ratio</dc:subject><dc:subject>rooftop solar power plant</dc:subject><dc:subject>solar radiation measurement</dc:subject><dc:subject>power output optimization</dc:subject><dc:subject>solar irradiance</dc:subject><dc:description xml:lang="en">To overcome the fossil energy crisis due to the increasing need for electrical energy, new renewable energy sources are needed. Due to technological developments in the fields of transportation, industry, household, and commercial use. Indonesia’s geography has the potential to apply new renewable energy, more specifically photovoltaic (PV). However, it is greatly influenced by environmental factors such as solar radiation, voltage, which have an impact on the output power efficiency and performance. So, it is necessary to test both measurements and calculations to see the optimization of output power and PV efficiency. From previous research, it has not been carried out, especially in the experimental method Universitas Pamulang: measurement and empirical and for a sufficiently high capacity with the aim of optimal output power. Methods of measuring sunlight intensity, voltage and current, the calculation of converting sunlight intensity to solar constellation, power, efficiency, and performance ratio (PR). The average value being 721 W/m2 an efficiency value of 19.9% and a value PR is obtained of 0.967 or 96.7% is still realistic. So that the system is declared optimal.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i1.5557</dc:identifier><dc:identifier>10.11591/eei.v13i1.5557</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 1 (2024); 50-57</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5557/3515</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
4 sitasi
Crossref
Terindeks
lewat DOI
1 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Rozak, O. A., Triyanto, A., & Kusnadi, H. (2024). Efficiency and performance ratio of photovoltaics on a 50 kWp Universitas Pamulang Viktor rooftop solar power plant. Bulletin of Electrical Engineering and Informatics, 13(1), 50–57. https://doi.org/10.11591/eei.v13i1.5557
Salin
IEEE
O. A. Rozak, A. Triyanto, and H. Kusnadi, “Efficiency and performance ratio of photovoltaics on a 50 kWp Universitas Pamulang Viktor rooftop solar power plant,” Bulletin of Electrical Engineering and Informatics, vol. 13, no. 1, pp. 50–57, 2024, doi: 10.11591/eei.v13i1.5557.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.