Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

IoT-based health information system using MitApp for abnormal electrocardiogram signal monitoring

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · hlm. 1103–1110

DOI
10.11591/eei.v13i2.5205
ISSN
2089-3191, 2302-9285
Terbit
2024-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Information systems are currently developing very rapidly, and this is inseparable from the role of internet of things (IoT) technology, especially in the world of telemedicine. MitApp is an open-source application that can be used to monitor electrocardiogram (ECG) signals in real-time. The aim of this study is to develop an IoT-based ECG signal monitoring system that utilizes the MitApp application to detect abnormal ECG signals that are characterized by symptoms of cardiac arrhythmias. To process ECG signal data obtained from lead electrode results, the research method utilizes Arduino Uno as a microcontroller. The result is then displayed on the thin film transistor (TFT) layer using the Nextion module. The ESP32 module is used as a Wi-Fi module to send data to the MitApp app on a smartphone. The results showed that the results of the comparison test of ECG signal module data with ECG simulator tools with beats per minute values of 60, 80, 100, 120, and 140 obtained an error rate of 0.05. Based on these results, there is potential to develop this feature and integrate the system with the patient management system to improve the effectiveness of remote monitoring.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 113 tautan kepenulisan bersama · 52 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Poltekkes Kemenkes Surabaya
  • University of Pembangunan Nasional Veteran Jawa Timur
  • Padjadjaran University
  • Universitas Trunodjoyo Madura
  • Universiti Brunei Darussalam
  • Bani-Waleed University
  • Opole University of Technology
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdussalam Ali AhmedBani-Waleed University5
Sumber SumberPoltekkes Kemenkes Surabaya3
Endang Dian SetioningsihPoltekkes Kemenkes Surabaya3
Sugeng Iwan SetyobudiPoltekkes Kemenkes Malang3
Wahyu LestariUniversity of Pembangunan Nasional Veteran Jawa Timur2
Grzegorz KrólczykOpole University of Technology2
Roichatun NashichahPoltekkes Kemenkes Surabaya2
Herianto HeriantoUniversitas Gadjah Mada2
Vugar Hajimahmud AbdullayevAzerbaijan State Oil and Industry University2
Endro YuliantoPoltekkes Kemenkes Surabaya1
Umaimah Mitsalia Ummi SalwaUniversitas Airlangga1
Tri Bowo IndartoPoltekkes Kemenkes Surabaya1
Hanny HafiarPadjadjaran University1
Syauqy LukmanAustralian National University1
Putri LimiliaPadjadjaran University1
Kholidil AminPadjadjaran University1
Triana RahmawatiAfiliasi tidak diketahui1
I Putu Alit PawanaRumah Sakit Dokter Soetomo1
Alfian Ma’arifUniversitas Ahmad Dahlan1
Iswanto SuwarnoMuhammadiyah University of Yogyakarta1
Faikul UmamUniversitas Trunodjoyo Madura1
Muhammad FuadUniversitas Trunodjoyo Madura1
Vugar AbdullayevAfiliasi tidak diketahui1
Abd KholiqAfiliasi tidak diketahui1
Lamidi LamidiAfiliasi tidak diketahui1
Farid AmrinsaniAfiliasi tidak diketahui1
Hafizh Aushaf MahdyAfiliasi tidak diketahui1
Ragimova NazilaAfiliasi tidak diketahui1
Eva Yulia PuspaningrumUniversity of Pembangunan Nasional Veteran Jawa Timur1
I Gede Susrama Mas DiyasaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Deshinta Arrova DewiINTI International University1
Sayyidah HumairahUniversity of Pembangunan Nasional Veteran Jawa Timur1
Fara Disa DurryUniversity of Pembangunan Nasional Veteran Jawa Timur1
Rangga Laksana AryanandaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Ade Silvia HandayaniPoliteknik Negeri Sriwijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">IoT-based health information system using MitApp for abnormal electrocardiogram signal monitoring</dc:title><dc:creator>Bedjo Utomo</dc:creator><dc:creator>Triwiyanto Triwiyanto</dc:creator><dc:creator>Sari Luthfiyah</dc:creator><dc:creator>Wahyu Caesarendra</dc:creator><dc:creator>Vijay Anant Athavale</dc:creator><dc:subject>Internet of Things</dc:subject><dc:subject>ECG monitoring</dc:subject><dc:subject>ECG anomaly detection</dc:subject><dc:subject>cardiac arrhythmias</dc:subject><dc:subject>telemedicine</dc:subject><dc:subject>Arduino Uno</dc:subject><dc:subject>ESP32 Wi-Fi module</dc:subject><dc:subject>remote patient monitoring</dc:subject><dc:description xml:lang="en">Information systems are currently developing very rapidly, and this is inseparable from the role of internet of things (IoT) technology, especially in the world of telemedicine. MitApp is an open-source application that can be used to monitor electrocardiogram (ECG) signals in real-time. The aim of this study is to develop an IoT-based ECG signal monitoring system that utilizes the MitApp application to detect abnormal ECG signals that are characterized by symptoms of cardiac arrhythmias. To process ECG signal data obtained from lead electrode results, the research method utilizes Arduino Uno as a microcontroller. The result is then displayed on the thin film transistor (TFT) layer using the Nextion module. The ESP32 module is used as a Wi-Fi module to send data to the MitApp app on a smartphone. The results showed that the results of the comparison test of ECG signal module data with ECG simulator tools with beats per minute values of 60, 80, 100, 120, and 140 obtained an error rate of 0.05. Based on these results, there is potential to develop this feature and integrate the system with the patient management system to improve the effectiveness of remote monitoring.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i2.5205</dc:identifier><dc:identifier>10.11591/eei.v13i2.5205</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 1103-1110</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5205/3633</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>