Energy efficiency in activated sludge process using adaptive iterative learning control with PI ABAC

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · hlm. 885–892

DOI
10.11591/eei.v13i2.5095
ISSN
2089-3191, 2302-9285
Terbit
2024-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper proposed an iterative learning control (ILC) with a feedback regulator based on proportional integral ammonium-based aeration control (PI ABAC) to improve dissolved oxygen control through data learning of iteration data. The proposed controller's performance is evaluated using benchmark simulation model no. 1. (BSM1). The assessments focused on four main areas: effluent violation, effluent quality, aeration energy, and overall cost index. The proposed ILC PI ABAC controller's effectiveness is evaluated by comparing the performance of the activated sludge process to the BSM1 PI and feedback PI ABAC under three different weather conditions: dry, rain, and storm. The improvement of the proposed method over BSM1 PI is demonstrated by a reduction in aeration energy of up to 24%. In conclusion, if the proposed ILC PI ABAC controller is given enough information, it can be quite successful in achieving energy efficiency.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 23 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Sarawak
  • University of Technology Malaysia
  • Politeknik Kuching Sarawak
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Asrani LitUniversiti Malaysia Sarawak1
Kuryati KipliUniversiti Malaysia Sarawak1
Rohana SapawiUniversiti Malaysia Sarawak1
Fariza MahyanPoliteknik Kuching Sarawak1
Mohd Fua’ad RahmatUniversity of Technology Malaysia1
Norhaliza Abdul WahabUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Energy efficiency in activated sludge process using adaptive iterative learning control with PI ABAC</dc:title><dc:creator>Maimun Huja Husin</dc:creator><dc:creator>Mohamad Faizrizwan Mohd Sabri</dc:creator><dc:creator>Kismet Anak Hong Ping</dc:creator><dc:creator>Norazlina Bateni</dc:creator><dc:creator>Shamsiah binti Suhaili</dc:creator><dc:subject>iterative learning control</dc:subject><dc:subject>activated sludge process</dc:subject><dc:subject>aeration control</dc:subject><dc:subject>PI controller</dc:subject><dc:subject>dissolved oxygen control</dc:subject><dc:subject>aeration energy efficiency</dc:subject><dc:subject>adaptive control</dc:subject><dc:subject>weather conditions</dc:subject><dc:subject>effluent quality</dc:subject><dc:subject>wastewater treatment</dc:subject><dc:description xml:lang="en">This paper proposed an iterative learning control (ILC) with a feedback regulator based on proportional integral ammonium-based aeration control (PI ABAC) to improve dissolved oxygen control through data learning of iteration data. The proposed controller's performance is evaluated using benchmark simulation model no. 1. (BSM1). The assessments focused on four main areas: effluent violation, effluent quality, aeration energy, and overall cost index. The proposed ILC PI ABAC controller's effectiveness is evaluated by comparing the performance of the activated sludge process to the BSM1 PI and feedback PI ABAC under three different weather conditions: dry, rain, and storm. The improvement of the proposed method over BSM1 PI is demonstrated by a reduction in aeration energy of up to 24%. In conclusion, if the proposed ILC PI ABAC controller is given enough information, it can be quite successful in achieving energy efficiency.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i2.5095</dc:identifier><dc:identifier>10.11591/eei.v13i2.5095</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 885-892</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5095/3614</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>