Akses terbuka
Jurnal
SINTA 1
The development of a virtual simulator for a novel design surgical tool in endoscopic endonasal transsphenoidal surgery
Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 3 (2021) · hlm. 1368–1379
ISSN 2089-3191, 2302-9285
Terbit 2021-06-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Endoscopic endonasal transsphenoidal surgery (EETS) is a standard procedure to treat the pituitary adenoma, a tumor in the pituitary gland that causes malfunction of hormones. Although the method is substantially minimal invasive, the surgeon may encounter intricacies. The major challenges are narrow surgery pathway, limited working area, lack of case studies for practicing, steep learning curve owing to the intricate steps, and the tool insertion risk. To ease the neurosurgeons, this research focuses on the development and testing of the surgical simulator based on the pathway guidance and the interchangeable surgical instrument tooltip. The system was tested in human cadaver-based experiments with interchangeability in terms of function and the performance of the simulator in terms of the benefits. The experiments demonstrate the augmentation in the learning skill of the user through the simulator based on the completion time assessment and the error reduction. Furthermore, the satisfaction level of the interchangeable surgical tool, which was found using sliding switch and gripper scored 71.40%, the interchangeable tooltip function, which is a novel function to participants scored 85.6% and the practical use had 77%. The geometric aspect of the interchangeable tool scored lowest (62.80%) and was found to be moderate among the neurosurgeons.
Jaringan kolaborasi para penulis
10 penulis ·
16 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mahidol University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The development of a virtual simulator for a novel design surgical tool in endoscopic endonasal transsphenoidal surgery</dc:title><dc:creator>Nantida Nillahoot</dc:creator><dc:creator>Branesh Madhavan Pillai</dc:creator><dc:creator>Sorayouth Chumnanvej</dc:creator><dc:creator>Jackrit Suthakorn</dc:creator><dc:subject>virtual surgical simulator</dc:subject><dc:subject>endoscopic endonasal transsphenoidal surgery</dc:subject><dc:subject>pituitary adenoma</dc:subject><dc:subject>surgical training</dc:subject><dc:subject>learning curve</dc:subject><dc:subject>surgical error reduction</dc:subject><dc:description xml:lang="en">Endoscopic endonasal transsphenoidal surgery (EETS) is a standard procedure to treat the pituitary adenoma, a tumor in the pituitary gland that causes malfunction of hormones. Although the method is substantially minimal invasive, the surgeon may encounter intricacies. The major challenges are narrow surgery pathway, limited working area, lack of case studies for practicing, steep learning curve owing to the intricate steps, and the tool insertion risk. To ease the neurosurgeons, this research focuses on the development and testing of the surgical simulator based on the pathway guidance and the interchangeable surgical instrument tooltip. The system was tested in human cadaver-based experiments with interchangeability in terms of function and the performance of the simulator in terms of the benefits. The experiments demonstrate the augmentation in the learning skill of the user through the simulator based on the completion time assessment and the error reduction. Furthermore, the satisfaction level of the interchangeable surgical tool, which was found using sliding switch and gripper scored 71.40%, the interchangeable tooltip function, which is a novel function to participants scored 85.6% and the practical use had 77%. The geometric aspect of the interchangeable tool scored lowest (62.80%) and was found to be moderate among the neurosurgeons.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i3.3037</dc:identifier><dc:identifier>10.11591/eei.v10i3.3037</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 3 (2021); 1368-1379</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3037/2228</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Terindeks
lewat DOI
2 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Nillahoot, N., Pillai, B. M., Chumnanvej, S., & Suthakorn, J. (2021). The development of a virtual simulator for a novel design surgical tool in endoscopic endonasal transsphenoidal surgery. Bulletin of Electrical Engineering and Informatics, 10(3), 1368–1379. https://doi.org/10.11591/eei.v10i3.3037
Salin
IEEE
N. Nillahoot, B. M. Pillai, S. Chumnanvej, and J. Suthakorn, “The development of a virtual simulator for a novel design surgical tool in endoscopic endonasal transsphenoidal surgery,” Bulletin of Electrical Engineering and Informatics, vol. 10, no. 3, pp. 1368–1379, 2021, doi: 10.11591/eei.v10i3.3037.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.