Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Hybrid islanding detection method based on the rate of change of frequency and load impedance

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 6 (2021) · hlm. 2997–3006

DOI
10.11591/eei.v10i6.3246
ISSN
2089-3191, 2302-9285
Terbit
2021-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Interconnection of distributed generation (DG) in distribution system will result in formation of islands in the event of loss of main supply. This scenario is harmful to the power system, hence quick detection is critical to halt the formation of islands. Among the common passive and active detection methods available, the hybrid detection method is identified as the most reliable method. This paper proposes a new hybrid method using the combination of passive and active technique which is the rate of change of frequency (ROCOF) and load impedance, respectively. The passive method works when the value of ROCOF exceeds the threshold value which is set at 0.3Hz/s. The active method works when it detects low value of ROCOF and immediately inject a pre-specified load into the system to increase the ROCOF value up to its threshold value. Simulation study on different case studies is carried out on distribution test system to evaluate the performance of the proposed method. Results show that this method is effective in detecting any events that could result in islanding.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 76 tautan kepenulisan bersama · 24 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • Universiti Teknikal Malaysia Melaka
  • Universiti Tenaga Nasional
  • Universiti Putra Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nur Fadilah Ab AzizUniversiti Tenaga Nasional8
Siti Zaliha Mohammad NoorUniversiti Teknologi MARA4
Yusnita Mohd AliUniversiti Teknologi MARA3
Mohammad Shariful IslamUniversiti Teknologi MARA3
Mohd Danish Irfan Mohd SufianUniversiti Teknologi MARA3
Nur Diyana Shahirah Mohd ZainUniversiti Teknologi MARA3
Nofri Yenita DahlanUniversiti Teknologi MARA2
Arvind RajUniversiti Tenaga Nasional2
Elia Erwani HassanUniversiti Teknikal Malaysia Melaka1
Nur Syifa Nasyrah RazaliUniversiti Teknologi MARA1
Nurfadzilah AhmadUniversiti Teknologi MARA1
Mohamad Fani SulaimaUniversiti Teknikal Malaysia Melaka1
Md Nazri OthmanUniversiti Teknikal Malaysia Melaka1
Hyreil Anuar KasdirinUniversiti Teknikal Malaysia Melaka1
Mohamed Hafiz bin Md IsaUniversiti Teknikal Malaysia Melaka1
Ismail MusirinUniversiti Teknologi MARA1
Muhammad Murtadha OthmanUniversiti Teknologi MARA1
Mohammad Lutfi OthmanUniversiti Putra Malaysia1
Mohd Affendi Ismail SalimUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Hybrid islanding detection method based on the rate of change of frequency and load impedance</dc:title><dc:creator>Hasmaini Mohamad</dc:creator><dc:creator>Zuhaila Mat Yasin</dc:creator><dc:creator>Nur Ashida Salim</dc:creator><dc:creator>Bibi Norasiqin Sheikh Rahimullah</dc:creator><dc:creator>Kanendra Naidu</dc:creator><dc:subject>islanding detection</dc:subject><dc:subject>rate of change of frequency</dc:subject><dc:subject>load impedance</dc:subject><dc:subject>hybrid detection</dc:subject><dc:subject>distributed generation</dc:subject><dc:subject>distribution systems</dc:subject><dc:subject>active islanding detection</dc:subject><dc:subject>passive islanding detection</dc:subject><dc:description xml:lang="en">Interconnection of distributed generation (DG) in distribution system will result in formation of islands in the event of loss of main supply. This scenario is harmful to the power system, hence quick detection is critical to halt the formation of islands. Among the common passive and active detection methods available, the hybrid detection method is identified as the most reliable method. This paper proposes a new hybrid method using the combination of passive and active technique which is the rate of change of frequency (ROCOF) and load impedance, respectively. The passive method works when the value of ROCOF exceeds the threshold value which is set at 0.3Hz/s. The active method works when it detects low value of ROCOF and immediately inject a pre-specified load into the system to increase the ROCOF value up to its threshold value. Simulation study on different case studies is carried out on distribution test system to evaluate the performance of the proposed method. Results show that this method is effective in detecting any events that could result in islanding.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i6.3246</dc:identifier><dc:identifier>10.11591/eei.v10i6.3246</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 6 (2021); 2997-3006</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3246/2392</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>