Akses terbuka
Jurnal
SINTA 1
Optimized weighted non-local mean filter for enhanced denoising and improved quality of medical images
Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 5 (2025) · hlm. 3611–3621
ISSN 2089-3191, 2302-9285
Terbit 2025-10-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Image quality is significantly influenced by noise, light, and artifacts, particularly in medical images where precision is essential for accurate diagnosis. Denoising is a significant pre-processing for enhancing the overall quality of images to enable efficient classification, feature extraction, and segmentation. Conventional denoising filters smooth out boundaries and lose texture because they are ineffective to process color images. To address these limitations, a weighted factor-based non-local means (WF+NLM) filter is proposed as an improvement over the non-local means (NLM) filter, with an additional weight factor based on pixel similarity. This addition reduces blurring while maintaining fine details, resulting in improved quality. The proposed filter performs effectively in blood smear images, with a peak signal-to-noise ratio (PSNR) of 39.6904, SSIM of 0.9551, and gradient SSIM of 0.9889. Statistical tests indicates that the WF+NLM filter improves image quality in terms of structure, gradients, and feature similarity. Statistical inference for a one-tailed paired t-test validates statistical significance with the highest t value of 9.323829 with p-value 0.00037 by the wavelet-based non-local moment mean (W-NMM) filter asserts higher image restoration quality.
Jaringan kolaborasi para penulis
5 penulis ·
6 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Avinashilingam University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimized weighted non-local mean filter for enhanced denoising and improved quality of medical images</dc:title><dc:creator>Aiswarya Senthilvel</dc:creator><dc:creator>Marimuthu Krishnaveni</dc:creator><dc:creator>Subashini Parthasarathy</dc:creator><dc:subject>non-local means</dc:subject><dc:subject>image denoising</dc:subject><dc:subject>medical image enhancement</dc:subject><dc:subject>blood smear images</dc:subject><dc:subject>image quality assessment</dc:subject><dc:subject>texture preservation</dc:subject><dc:description xml:lang="en">Image quality is significantly influenced by noise, light, and artifacts, particularly in medical images where precision is essential for accurate diagnosis. Denoising is a significant pre-processing for enhancing the overall quality of images to enable efficient classification, feature extraction, and segmentation. Conventional denoising filters smooth out boundaries and lose texture because they are ineffective to process color images. To address these limitations, a weighted factor-based non-local means (WF+NLM) filter is proposed as an improvement over the non-local means (NLM) filter, with an additional weight factor based on pixel similarity. This addition reduces blurring while maintaining fine details, resulting in improved quality. The proposed filter performs effectively in blood smear images, with a peak signal-to-noise ratio (PSNR) of 39.6904, SSIM of 0.9551, and gradient SSIM of 0.9889. Statistical tests indicates that the WF+NLM filter improves image quality in terms of structure, gradients, and feature similarity. Statistical inference for a one-tailed paired t-test validates statistical significance with the highest t value of 9.323829 with p-value 0.00037 by the wavelet-based non-local moment mean (W-NMM) filter asserts higher image restoration quality.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i5.9549</dc:identifier><dc:identifier>10.11591/eei.v14i5.9549</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 5 (2025); 3611-3621</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9549/4403</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Belum diperiksa
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Senthilvel, A., Krishnaveni, M., & Parthasarathy, S. (2025). Optimized weighted non-local mean filter for enhanced denoising and improved quality of medical images. Bulletin of Electrical Engineering and Informatics, 14(5), 3611–3621. https://doi.org/10.11591/eei.v14i5.9549
Salin
IEEE
A. Senthilvel, M. Krishnaveni, and S. Parthasarathy, “Optimized weighted non-local mean filter for enhanced denoising and improved quality of medical images,” Bulletin of Electrical Engineering and Informatics, vol. 14, no. 5, pp. 3611–3621, 2025, doi: 10.11591/eei.v14i5.9549.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.