Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative analysis of unidirectional and bidirectional RNNs for ECG arrhythmia detection using augmented MIT-BIH data

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 1 (2026) · hlm. 712–722

DOI
10.11591/eei.v15i1.10893
ISSN
2089-3191, 2302-9285
Terbit
2026-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Accurate classification of electrocardiogram (ECG) signals is essential for early arrhythmia detection. This study compares the performance of unidirectional and bidirectional recurrent neural networks (RNN), specifically gated recurrent unit (GRU)-based architectures, for classifying ECG beats as normal or arrhythmic. ECG data were sourced from the MIT-BIH Arrhythmia Database using the WFDB toolkit. Each beat was segmented into a 128-sample window centered on the R-peak and labeled into two classes. To address severe class imbalance (6,279 normal vs. 43 arrhythmic beats), data augmentation techniques—jittering and scaling—were applied, resulting in a balanced dataset. Both models were trained under identical conditions, with evaluation based on accuracy, precision, recall, F1-score, and other statistical metrics. The unidirectional RNN achieved poor recall (9.0%) despite high precision, yielding an overall accuracy of 54.0%. In contrast, the bidirectional RNN significantly outperformed, achieving 98.17% accuracy, 98.39% precision, 97.92% recall, and a 98.16% F1-score. The results demonstrate that bidirectional temporal modeling provides substantial improvements in ECG classification, especially for detecting minority class arrhythmias. This study highlights the importance of both data augmentation and model architecture in developing effective deep learning solutions for real-time ECG analysis and clinical diagnostics.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Easwari Engineering College
  • Saveetha University
  • Villa College
  • Centre Universitaire de Mila
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Vengadeshwaran VeluCentre Universitaire de Mila2
S. KavithaEaswari Engineering College1
Chinthamani B.Easwari Engineering College1
Balasubramanian Suresh Chander KapaliAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparative analysis of unidirectional and bidirectional RNNs for ECG arrhythmia detection using augmented MIT-BIH data</dc:title><dc:creator>Sabura Banu Urundai Meeran</dc:creator><dc:creator>Nafeena Abdul Munaf</dc:creator><dc:subject>ECG arrhythmia detection</dc:subject><dc:subject>bidirectional recurrent neural network</dc:subject><dc:subject>gated recurrent unit</dc:subject><dc:subject>MIT-BIH arrhythmia database</dc:subject><dc:subject>data augmentation</dc:subject><dc:subject>class imbalance</dc:subject><dc:subject>ECG beat classification</dc:subject><dc:subject>real-time ECG analysis</dc:subject><dc:description xml:lang="en">Accurate classification of electrocardiogram (ECG) signals is essential for early arrhythmia detection. This study compares the performance of unidirectional and bidirectional recurrent neural networks (RNN), specifically gated recurrent unit (GRU)-based architectures, for classifying ECG beats as normal or arrhythmic. ECG data were sourced from the MIT-BIH Arrhythmia Database using the WFDB toolkit. Each beat was segmented into a 128-sample window centered on the R-peak and labeled into two classes. To address severe class imbalance (6,279 normal vs. 43 arrhythmic beats), data augmentation techniques—jittering and scaling—were applied, resulting in a balanced dataset. Both models were trained under identical conditions, with evaluation based on accuracy, precision, recall, F1-score, and other statistical metrics. The unidirectional RNN achieved poor recall (9.0%) despite high precision, yielding an overall accuracy of 54.0%. In contrast, the bidirectional RNN significantly outperformed, achieving 98.17% accuracy, 98.39% precision, 97.92% recall, and a 98.16% F1-score. The results demonstrate that bidirectional temporal modeling provides substantial improvements in ECG classification, especially for detecting minority class arrhythmias. This study highlights the importance of both data augmentation and model architecture in developing effective deep learning solutions for real-time ECG analysis and clinical diagnostics.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i1.10893</dc:identifier><dc:identifier>10.11591/eei.v15i1.10893</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 1 (2026); 712-722</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10893/4595</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>