Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Integrated-grid energy system for supplying reliable electricity to health sectors using grey wolf optimizer algorithms

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 4 (2026) · hlm. 2888–2899

DOI
10.11591/eei.v15i4.10778
ISSN
2089-3191, 2302-9285
Terbit
2026-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This study evaluates the techno-economic and environmental performance of various hybrid renewable energy system (HRES) optimized using the gray wolf optimization (GWO) algorithm, aimed at supplying reliable and sustainable energy to a health centre. Multiple system configurations were analyzed, including combinations of photovoltaic (PV), wind, diesel generator (DG), battery storage, and the electrical grid. Key performance metrics assessed include the cost of energy (COE), net present cost (NPC), payback period, annual utility bill savings, carbon dioxide (CO2) emissions, and annual fuel consumption. Results indicate that all hybrid systems significantly outperform the conventional grid-only base case across all evaluated parameters. The base case exhibits the highest COE ($0.159/kWh) and CO2 emissions (8,549 tons/year), underscoring the economic and environmental drawbacks of sole grid dependency. In contrast, the PV/wind/diesel/grid configuration achieved the lowest COE ($0.013676/kWh) and substantial reductions in emissions (2,349 tons/year), with a favorable payback period of 4.5 years. The optimization results highlight the effectiveness of GWO in balancing economic viability with environmental sustainability. Among the configurations, the PV/wind/grid and PV/wind/diesel/grid systems emerged as the most cost-effective and environmentally beneficial solutions. These findings highlight the potential of intelligently optimized hybrid renewable systems to deliver reliable, low-cost, and low-emission energy to critical infrastructure, such as healthcare centers.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 119 tautan kepenulisan bersama · 44 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Abuja
  • University of Nigeria
  • Enugu State University of Science and Technology
  • Federal Capital Territory Administration
  • Caritas University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sadiq Abubakar UmarUniversity of Abuja4
Sochima Vincent EgoigweUniversity of Nigeria4
Matthew Chinedu OdoUniversity of Nigeria4
Jacob Kehinde OgunjuyigbeUniversity of Abuja4
Chijioke EJIMOFORUniversity of Abuja3
Taiwo Felix AdebayoUniversity of Nigeria2
Chikammadu Emmanuel OpataEnugu State University of Science and Technology2
Ohagwu Walte AkachukwuEnugu State University of Science and Technology2
Sardauna IbrahimFederal Capital Territory Administration2
Oluyinka Olugbenga AinaAfiliasi tidak diketahui2
Onyekachukwu Denis OzuluAfiliasi tidak diketahui2
Issac Ojochogwu OnuhAfiliasi tidak diketahui2
Ikenna Chuddy MbamaluCaritas University2
Thank God Izuchukwu OzueAfiliasi tidak diketahui2
Muncho Josephine MbunweUniversity of Nigeria2
Emmanuel Majiyebo EronuUniversity of Abuja2
Nnaemeka Genesis AjahUniversity of Nigeria2
Isaac Ojochogwu OnuhAfiliasi tidak diketahui2
Kafayat AdeyemiUniversity of Abuja2
Ngang Bassey NgangUniversity of Abuja2
Stephen Adole BensonUniversity of Abuja2
Solomon Bala OkohUniversity of Abuja2
Iboi EnduranceUniversity of Abuja2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Integrated-grid energy system for supplying reliable electricity to health sectors using grey wolf optimizer algorithms</dc:title><dc:creator>Olumuyiwa Ajibola Awoniyi</dc:creator><dc:creator>Evans Chinemezu Ashigwuike</dc:creator><dc:creator>Timothy Oluwaseun Araoye</dc:creator><dc:subject>hybrid renewable energy systems</dc:subject><dc:subject>grey wolf optimizer</dc:subject><dc:subject>photovoltaic systems</dc:subject><dc:subject>wind energy</dc:subject><dc:subject>diesel generator</dc:subject><dc:subject>battery energy storage</dc:subject><dc:subject>grid-connected systems</dc:subject><dc:subject>energy costs</dc:subject><dc:subject>CO2 emissions</dc:subject><dc:subject>techno-economic analysis</dc:subject><dc:subject>payback period</dc:subject><dc:description xml:lang="en">This study evaluates the techno-economic and environmental performance of various hybrid renewable energy system (HRES) optimized using the gray wolf optimization (GWO) algorithm, aimed at supplying reliable and sustainable energy to a health centre. Multiple system configurations were analyzed, including combinations of photovoltaic (PV), wind, diesel generator (DG), battery storage, and the electrical grid. Key performance metrics assessed include the cost of energy (COE), net present cost (NPC), payback period, annual utility bill savings, carbon dioxide (CO2) emissions, and annual fuel consumption. Results indicate that all hybrid systems significantly outperform the conventional grid-only base case across all evaluated parameters. The base case exhibits the highest COE ($0.159/kWh) and CO2 emissions (8,549 tons/year), underscoring the economic and environmental drawbacks of sole grid dependency. In contrast, the PV/wind/diesel/grid configuration achieved the lowest COE ($0.013676/kWh) and substantial reductions in emissions (2,349 tons/year), with a favorable payback period of 4.5 years. The optimization results highlight the effectiveness of GWO in balancing economic viability with environmental sustainability. Among the configurations, the PV/wind/grid and PV/wind/diesel/grid systems emerged as the most cost-effective and environmentally beneficial solutions. These findings highlight the potential of intelligently optimized hybrid renewable systems to deliver reliable, low-cost, and low-emission energy to critical infrastructure, such as healthcare centers.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i4.10778</dc:identifier><dc:identifier>10.11591/eei.v15i4.10778</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 4 (2026); 2888-2899</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/10778/4848</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>