Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Abnormal heart rate detection through real-time heart monitoring application

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 4 (2023) · hlm. 2495–2505

DOI
10.11591/eei.v12i4.4933
ISSN
2089-3191, 2302-9285
Terbit
2023-03-15
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Health monitoring that requires doctors and patients at the healthcare center may not be practical during the coronavirus disease 2019 (COVID-19) pandemic. Alternatively, mobile health (mHealth) should be embraced to minimize contact between patients and healthcare personnel. This research aims to enhance the detection of abnormal heart rate (HR) detection by developing a real-time heart rate monitoring (RTHM) application. Sixteen healthy adults participated in a physical real-time HR monitoring testbed. Participants HR was measured for three minutes resting and three minutes performing moderate-intensity physical activity. The results were compared with the polar beat app. Additionally, the energy consumption, the time taken to receive an alarm message, and an acceptance test were analyzed. The app is acceptably accurate, the mean absolute percentage error less than 2%. The response time to receive the alarm message is 30 seconds on average, which is under an acceptable range of medical standards. Moreover, the app is power efficient, 477 mW on average. Participants show a positive attitude towards using RTHM. RTHM is expected to provide a more plausible tool for monitoring the heart towards enhancing abnormal HR detection by promoting patient-oriented healthcare and minimizing sudden deaths due to heart failure.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 92 tautan kepenulisan bersama · 34 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Tenaga Nasional
  • Universiti Putra Malaysia
  • Politeknik Muadzam Shah
  • Universiti Teknologi Petronas
  • State University of Malang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sabrina AhmadUniversiti Teknikal Malaysia Melaka4
Nik Nurdini WolseleyUniversiti Teknikal Malaysia Melaka4
Burhanuddin Mohd AboobaiderUniversiti Teknikal Malaysia Melaka4
Ngo Hea ChoonUniversiti Teknikal Malaysia Melaka3
Ummi Raba’ah HashimAfiliasi tidak diketahui2
Kasturi KanchymalayUniversiti Teknikal Malaysia Melaka2
Abbas M. Al-GhailiUniversiti Tenaga Nasional2
Zul-Azri IbrahimUniversiti Tenaga Nasional2
Hasventhran BaskaranUniversiti Tenaga Nasional2
Hairoladenan KasimUniversiti Putra Malaysia2
Mohd Hilmi HasanUniversiti Teknologi Petronas2
Nur Dalila AbdullahPoliteknik Muadzam Shah2
Teo Hong ChunUniversiti Teknikal Malaysia Melaka1
Aji Prasetya WibawaState University of Malang1
Martina AliUniversiti Teknikal Malaysia Melaka1
Rahillda Nadhirah Norizzaty RahiddinUniversiti Teknikal Malaysia Melaka1
Rafizah Ab RahmanPoliteknik Muadzam Shah1
Syazwani Arissa Shah HairiUniversiti Tenaga Nasional1
Noor Afiza Mohd AriffinUniversiti Putra Malaysia1
Saravanan MuthaiyahUniversiti Putra Malaysia1
Chiah Chin LimUniversiti Teknikal Malaysia Melaka1
Yuen Chin WongUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Abnormal heart rate detection through real-time heart monitoring application</dc:title><dc:creator>Ummi Namirah Hashim</dc:creator><dc:creator>Lizawati Binti Salahuddin</dc:creator><dc:creator>Ummi Rabaah Hashim</dc:creator><dc:creator>Mohd Hariz Naim</dc:creator><dc:creator>Raja Rina Raja Ikram</dc:creator><dc:creator>Fiza Abdul Rahim</dc:creator><dc:subject>abnormal heart rate detection</dc:subject><dc:subject>mobile health</dc:subject><dc:subject>COVID-19 pandemic</dc:subject><dc:subject>heart failure</dc:subject><dc:subject>physical activity</dc:subject><dc:subject>energy consumption</dc:subject><dc:subject>alarm response time</dc:subject><dc:subject>user acceptance</dc:subject><dc:subject>wearable heart rate monitoring</dc:subject><dc:description xml:lang="en">Health monitoring that requires doctors and patients at the healthcare center may not be practical during the coronavirus disease 2019 (COVID-19) pandemic. Alternatively, mobile health (mHealth) should be embraced to minimize contact between patients and healthcare personnel. This research aims to enhance the detection of abnormal heart rate (HR) detection by developing a real-time heart rate monitoring (RTHM) application. Sixteen healthy adults participated in a physical real-time HR monitoring testbed. Participants HR was measured for three minutes resting and three minutes performing moderate-intensity physical activity. The results were compared with the polar beat app. Additionally, the energy consumption, the time taken to receive an alarm message, and an acceptance test were analyzed. The app is acceptably accurate, the mean absolute percentage error less than 2%. The response time to receive the alarm message is 30 seconds on average, which is under an acceptable range of medical standards. Moreover, the app is power efficient, 477 mW on average. Participants show a positive attitude towards using RTHM. RTHM is expected to provide a more plausible tool for monitoring the heart towards enhancing abnormal HR detection by promoting patient-oriented healthcare and minimizing sudden deaths due to heart failure.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-03-15</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i4.4933</dc:identifier><dc:identifier>10.11591/eei.v12i4.4933</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 4 (2023); 2495-2505</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4933/3350</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>