Basis Weight Gain Tuning Using Different Types of Conventional Controllers

Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 1 (2016) · hlm. 62–71

DOI
10.11591/522
ISSN
2089-3191, 2302-9285
Terbit
2016-03-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Paper making is a vast, multidisciplinary technology that has expanded tremendously in recent years approaching to reach 20 million tons by 2020. As per demand implementation of necessary tools to optimize papermaking process and to increase the control precision, the precondition for stable operation and quality production is necessary. In the present work, an effort has been made to analyse gain tuning of Basis Weight output relative to the changing values of basis weight valve opening with step and variable input. The effects of the three constants KP, KD and KI for different types of conventional controllers as P, PD and PID controller are examined by adding a disturbance to the control system. The effects of various scaling gains are studied on the output of the system and are tuned to get the optimum output both for the step input as well as the varying input. Simulation results show that P, PD and PID controllers provide automatic tuning to preserve good performance for various operating conditions. An analysis of practical performance indices is presented by comparing results of three different conventional controllers. The system developed can be used to serve as platform for Control engineering techniques used in industries.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Graphic Era University
  • Graphic Era Hill University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sandeep Kumar SunoriGraphic Era Hill University3
Pradeep Kumar JunejaGraphic Era University3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Basis Weight Gain Tuning Using Different Types of Conventional Controllers</dc:title><dc:creator>Chandani Sharma</dc:creator><dc:creator>Anamika Bhatia Jain</dc:creator><dc:subject>basis weight control</dc:subject><dc:subject>papermaking</dc:subject><dc:subject>PID controller</dc:subject><dc:subject>P controller</dc:subject><dc:subject>PD control</dc:subject><dc:subject>controller tuning</dc:subject><dc:subject>controller gain tuning</dc:subject><dc:subject>step response</dc:subject><dc:subject>disturbance rejection</dc:subject><dc:subject>performance index</dc:subject><dc:description xml:lang="en">Paper making is a vast, multidisciplinary technology that has expanded tremendously in recent years approaching to reach 20 million tons by 2020. As per demand implementation of necessary tools to optimize papermaking process and to increase the control precision, the precondition for stable operation and quality production is necessary. In the present work, an effort has been made to analyse gain tuning of Basis Weight output relative to the changing values of basis weight valve opening with step and variable input. The effects of the three constants KP, KD and KI for different types of conventional controllers as P, PD and PID controller are examined by adding a disturbance to the control system. The effects of various scaling gains are studied on the output of the system and are tuned to get the optimum output both for the step input as well as the varying input. Simulation results show that P, PD and PID controllers provide automatic tuning to preserve good performance for various operating conditions. An analysis of practical performance indices is presented by comparing results of three different conventional controllers. The system developed can be used to serve as platform for Control engineering techniques used in industries.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/522</dc:identifier><dc:identifier>10.11591/522</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 1 (2016); 62-71</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language></oai_dc:dc>