Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Strategy to reduce solar power fluctuations by using battery energy storage system for UTeM’s grid-connected solar system

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3013–3022

DOI
10.11591/eei.v11i6.3862
ISSN
2089-3191, 2302-9285
Terbit
2022-09-29
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Recent years have witnessed the increasing uptake of solar photovoltaic (PV) installations, ranging from a few kilowatts for residential rooftops to a few megawatts for large-scale solar farms. One of the key challenges for the solar PV systems is its dependency on the solar energy, which is intermittent in nature and highly unpredictable. In this regard, battery energy storage system (BESS) is regarded as the effective solution that can smoothen the output power fluctuation from the solar PV system. Hence, this work utilized BESS that had fast response time with high power and energy density to reduce the solar output fluctuations from a real grid-connected solar system installed at the campus rooftop. The characteristic of the PV power fluctuation and the BESS storage requirement to smooth out the fluctuation within the allowable limit were determined and analyzed. More importantly, actual solar irradiance data with an interval of one minute was utilized in this work. The findings suggest that BESS with 66% of the installed solar capacity and 21% of the average daily solar generation of the installed system are required to smoothen the solar fluctuation that exceeds the ramp rate limit of 10%/min.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 82 tautan kepenulisan bersama · 33 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • National University of Malaysia
  • Universiti Tenaga Nasional
  • Karabük University
  • Federal College of Education (Technical) Bichi
  • Universitas Ahmad Dahlan
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nur Diana Izzani MasdzarifUniversiti Teknikal Malaysia Melaka4
Khairul Anwar IbrahimUniversiti Teknikal Malaysia Melaka4
Mau Teng AuUniversiti Tenaga Nasional4
Wan Juzaili JamilUniversity of Technology Malaysia2
Hasimah Abdul RahmanUniversity of Technology Malaysia2
Meysam ShamshiriUniversiti Teknikal Malaysia Melaka2
Mohd Arif Mohd AzmanUniversiti Teknikal Malaysia Melaka2
Zaheera Zainal AbidinUniversiti Teknikal Malaysia Melaka2
Nurul A. EmranUniversiti Teknikal Malaysia Melaka2
Mohamad Haireen Bin FatheliUniversiti Teknikal Malaysia Melaka1
Nur Izzati ZolkifriUniversiti Teknikal Malaysia Melaka1
Musa Yusup LadaUniversiti Teknikal Malaysia Melaka1
Kwan Yiew LauUniversity of Technology Malaysia1
Sarmid Shakir AbdulsattarUniversity of Technology Malaysia1
Chee Wei TanUniversity of Technology Malaysia1
Shahrin Md AyobUniversity of Technology Malaysia1
Yasir Shakir AbdulsattarKarabük University1
Ahmed Tijjani DahiruFederal College of Education (Technical) Bichi1
Kamaruzzaman SopianNational University of Malaysia1
Emy Zairah AhmadUniversiti Teknikal Malaysia Melaka1
Adnan Qahtan IbrahimNational University of Malaysia1
Mohd Suffian Ab RazakUniversiti Teknikal Malaysia Melaka1
Tole SutiknoUniversitas Ahmad Dahlan1
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka1
Abdelhak LekbirUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Strategy to reduce solar power fluctuations by using battery energy storage system for UTeM’s grid-connected solar system</dc:title><dc:creator>Wei Hown Tee</dc:creator><dc:creator>Yen Hoe Yee</dc:creator><dc:creator>Chin Kim Gan</dc:creator><dc:creator>Kyairul Azmi Baharin</dc:creator><dc:creator>Pi Hua Tan</dc:creator><dc:subject>solar power fluctuation</dc:subject><dc:subject>battery energy storage</dc:subject><dc:subject>grid-connected photovoltaic systems</dc:subject><dc:subject>power smoothing</dc:subject><dc:subject>solar irradiance</dc:subject><dc:subject>rooftop solar</dc:subject><dc:subject>energy storage sizing</dc:subject><dc:description xml:lang="en">Recent years have witnessed the increasing uptake of solar photovoltaic (PV) installations, ranging from a few kilowatts for residential rooftops to a few megawatts for large-scale solar farms. One of the key challenges for the solar PV systems is its dependency on the solar energy, which is intermittent in nature and highly unpredictable. In this regard, battery energy storage system (BESS) is regarded as the effective solution that can smoothen the output power fluctuation from the solar PV system. Hence, this work utilized BESS that had fast response time with high power and energy density to reduce the solar output fluctuations from a real grid-connected solar system installed at the campus rooftop. The characteristic of the PV power fluctuation and the BESS storage requirement to smooth out the fluctuation within the allowable limit were determined and analyzed. More importantly, actual solar irradiance data with an interval of one minute was utilized in this work. The findings suggest that BESS with 66% of the installed solar capacity and 21% of the average daily solar generation of the installed system are required to smoothen the solar fluctuation that exceeds the ramp rate limit of 10%/min.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-09-29</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.3862</dc:identifier><dc:identifier>10.11591/eei.v11i6.3862</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3013-3022</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3862/2970</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>