Control technique for power quality improvement of isolated wind power generation system

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 4 (2023) · hlm. 1881–1892

DOI
10.11591/eei.v12i4.5082
ISSN
2089-3191, 2302-9285
Terbit
2023-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Power quality (PQ) problems for renewable energy system (RES) is major challenge for using these systems. Amplitude, frequency, and waveform is important PQ parameters especially for standalone or isolated systems. In this paper we propose RES with wind turbine (WT) and permanent magnet synchronous generator (PMSG) to feed different loads (liner, non-liner) through AC-DC-AC converter. The PMSG operate with fuzzy logic inertia controller, to convert turbine torque form PU to Nm. The inverter stage in the converter operate according to proportional integral derivative (PID) controller with 3rd harmonic injection pulse width modulation (PWM) to regulate the AC voltage in load side. For the same case study and operating condition, we compared the result for system parameters when using ordinary PWM and using PID with 3rd harmonic injection. Voltages total harmonics distortion (THD) was less than 2% with liner loads, and 3.5% with non-liner load and the same was for current load, the voltage amplitude was between (1-1.03) PU under different wind speed by using the proposed controller.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Çankırı Karatekin University
  • Middle Technical University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Control technique for power quality improvement of isolated wind power generation system</dc:title><dc:creator>Göksu Görel</dc:creator><dc:creator>Inas Fadhil</dc:creator><dc:subject>power quality</dc:subject><dc:subject>permanent magnet synchronous generator</dc:subject><dc:subject>PID control</dc:subject><dc:subject>third harmonic injection</dc:subject><dc:subject>pulse width modulation</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>AC-DC-AC converter</dc:subject><dc:subject>voltage regulation</dc:subject><dc:description xml:lang="en">Power quality (PQ) problems for renewable energy system (RES) is major challenge for using these systems. Amplitude, frequency, and waveform is important PQ parameters especially for standalone or isolated systems. In this paper we propose RES with wind turbine (WT) and permanent magnet synchronous generator (PMSG) to feed different loads (liner, non-liner) through AC-DC-AC converter. The PMSG operate with fuzzy logic inertia controller, to convert turbine torque form PU to Nm. The inverter stage in the converter operate according to proportional integral derivative (PID) controller with 3rd harmonic injection pulse width modulation (PWM) to regulate the AC voltage in load side. For the same case study and operating condition, we compared the result for system parameters when using ordinary PWM and using PID with 3rd harmonic injection. Voltages total harmonics distortion (THD) was less than 2% with liner loads, and 3.5% with non-liner load and the same was for current load, the voltage amplitude was between (1-1.03) PU under different wind speed by using the proposed controller.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v12i4.5082</dc:identifier><dc:identifier>10.11591/eei.v12i4.5082</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 4 (2023); 1881-1892</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>