Blade imbalance fault identification in doubly fed induction generator through current signature analysis using wavelet transform

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 3 (2024) · hlm. 2131–2141

DOI
10.11591/eei.v13i3.5679
ISSN
2089-3191, 2302-9285
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Using wind turbines (WTs) equipped with doubly fed induction generators (DFIG) is a popular technology for generating renewable energy. To ensure safe operation, prompt maintenance, and better operational reliability, the induction generator used in wind energy must be monitored. In this paper, an analysis is carried out on stator currents of the DFIG machine in a wind farm to identify any blade imbalances in the wind farm. A fault characteristics extraction analysis is carried out on the machine stator currents to detect the fault in the system. Firstly, the mathematical equation of the DFIG blade unbalanced stator current is generated using the DFIG model. Secondly, Park's Transformation is used to modify the stator's 3-phase current. Further, by evaluating the feature frequency amplitude variation in the squared signal by doing a spectral analysis on the stator current vector's squared signal. Lastly, a Simulink model for the DFIG is developed. The suggested approach analyses the fault signal of the imbalanced blade fault at various wind velocities. The outcomes show that the suggested method for diagnosing impeller imbalance faults can successfully locate the fault.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • GLA University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Indresh YadavGLA University1
Gaurav Kumar GuptaGLA University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Blade imbalance fault identification in doubly fed induction generator through current signature analysis using wavelet transform</dc:title><dc:creator>Vivek Kushwaha</dc:creator><dc:creator>Arvind Kumar Yadav</dc:creator><dc:creator>Sanjay Kumar Maurya</dc:creator><dc:subject>doubly fed induction generator</dc:subject><dc:subject>wind turbines</dc:subject><dc:subject>current signature analysis</dc:subject><dc:subject>wavelet transform</dc:subject><dc:subject>stator current</dc:subject><dc:subject>fault diagnosis</dc:subject><dc:subject>wind farm monitoring</dc:subject><dc:subject>Park's transformation</dc:subject><dc:subject>spectral analysis</dc:subject><dc:subject>wind speed</dc:subject><dc:description xml:lang="en">Using wind turbines (WTs) equipped with doubly fed induction generators (DFIG) is a popular technology for generating renewable energy. To ensure safe operation, prompt maintenance, and better operational reliability, the induction generator used in wind energy must be monitored. In this paper, an analysis is carried out on stator currents of the DFIG machine in a wind farm to identify any blade imbalances in the wind farm. A fault characteristics extraction analysis is carried out on the machine stator currents to detect the fault in the system. Firstly, the mathematical equation of the DFIG blade unbalanced stator current is generated using the DFIG model. Secondly, Park's Transformation is used to modify the stator's 3-phase current. Further, by evaluating the feature frequency amplitude variation in the squared signal by doing a spectral analysis on the stator current vector's squared signal. Lastly, a Simulink model for the DFIG is developed. The suggested approach analyses the fault signal of the imbalanced blade fault at various wind velocities. The outcomes show that the suggested method for diagnosing impeller imbalance faults can successfully locate the fault.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i3.5679</dc:identifier><dc:identifier>10.11591/eei.v13i3.5679</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 3 (2024); 2131-2141</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5679/3750</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>