Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design of passive voltage balancer system for lead acid battery

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · hlm. 724–733

DOI
10.11591/eei.v13i2.5806
ISSN
2089-3191, 2302-9285
Terbit
2024-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The use of rechargeable batteries for electrical energy storage requires a voltage balancing system. The voltage balancing system requires monitoring in the use of rechargeable batteries so that they can be utilized properly and can improve the electrical energy storage system. In this research, a monitored lead acid battery voltage balancing system was designed so that the management of the battery voltage balance level and the storage of electrical energy in rechargeable batteries can be stored and used optimally. In this research a series of lead acid battery voltage detection and power dissipation circuits were designed. The power dissipation circuit uses the controlled shunt resistor method which is used when the voltage of the lead acid battery being charged exceeds the maximum voltage. This method is easy to implement and can display the value of the lead acid battery voltage and other parameters, so that it can be monitored by the user. The results obtained show that the average voltage error for batteries 1 and 2 is 0.09% and 0.3% respectively. The power dissipation circuit can dissipate lead acid battery power above the reference voltage VREF=±7 V, with a balanced voltage of 6.8 V at 140 minutes and 160 minutes.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 19 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Telkom University
  • Universitas Airlangga
  • Politeknik Negeri Bandung
  • Institut Teknologi Sepuluh Nopember
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dien RahmawatiTelkom University1
Achmad RizalTelkom University1
Prisma MegantoroUniversitas Airlangga1
Brahmantya Aji PramuditaTelkom University1
Kevin Octavianov AbdurohmanTelkom University1
Adi SoeprijantoInstitut Teknologi Sepuluh Nopember1
Jangkung RaharjoTelkom University1
Hermagasantos ZeinPoliteknik Negeri Bandung1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design of passive voltage balancer system for lead acid battery</dc:title><dc:creator>Bandiyah Sri Aprillia</dc:creator><dc:creator>Desri Kristina Silalahi</dc:creator><dc:creator>Kharisma Bani Adam</dc:creator><dc:creator>Putu Krishna Bhaskara Perteka Yuda</dc:creator><dc:subject>lead-acid batteries</dc:subject><dc:subject>voltage balancing</dc:subject><dc:subject>battery monitoring</dc:subject><dc:subject>shunt resistor</dc:subject><dc:subject>rechargeable batteries</dc:subject><dc:subject>electrical energy storage</dc:subject><dc:description xml:lang="en">The use of rechargeable batteries for electrical energy storage requires a voltage balancing system. The voltage balancing system requires monitoring in the use of rechargeable batteries so that they can be utilized properly and can improve the electrical energy storage system. In this research, a monitored lead acid battery voltage balancing system was designed so that the management of the battery voltage balance level and the storage of electrical energy in rechargeable batteries can be stored and used optimally. In this research a series of lead acid battery voltage detection and power dissipation circuits were designed. The power dissipation circuit uses the controlled shunt resistor method which is used when the voltage of the lead acid battery being charged exceeds the maximum voltage. This method is easy to implement and can display the value of the lead acid battery voltage and other parameters, so that it can be monitored by the user. The results obtained show that the average voltage error for batteries 1 and 2 is 0.09% and 0.3% respectively. The power dissipation circuit can dissipate lead acid battery power above the reference voltage VREF=±7 V, with a balanced voltage of 6.8 V at 140 minutes and 160 minutes.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i2.5806</dc:identifier><dc:identifier>10.11591/eei.v13i2.5806</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 724-733</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://doi.org/10.11591/eei.v13i2.5806</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>