Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

An optimization based deep learning approach for human activity recognition in healthcare monitoring

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 6 (2024) · hlm. 4236–4247

DOI
10.11591/eei.v13i6.8000
ISSN
2089-3191, 2302-9285
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Medical images are comprised of sensor measurements which help detect the characteristics of diseases. Computer-based analysis results in the early detection of diseases and suitable medications. Human activity recognition (HAR) is highly useful in applications related to medical care, fitness tracking, and patient data archiving. There are two kinds of data fed into the HAR system which are, image data and time series data of physical movements through accelerometers and gyroscopes present in smart devices. This study introduced crayfish optimization algorithm with long short term memory (COA-LSTM). The raw data is obtained from three datasets namely, WISDM, UCI-HAR, and PAMAP2 datasets; then, pre-processing helps in removal of unwanted information. The features from pre-processed data are reduced using principal component analysis and linear discriminant analysis (PCA-LDA). Finally, classification is performed using COA-LSTM where, the hyperparameters are fine-tuned with the help of COA. The suggested method achieves a classification accuracy of 98.23% for UCI-HAR dataset, whereas the existing techniques like convolutional neural network (CNN), multi-branch CNN-bidirectional LSTM, CNN with gated recurrent unit (GRU), ST-deep HAR, and Ensem-HAR obtain a classification accuracy of 91.98%, 96.37%, 96.20%, 97.7%, and 95.05%, respectively.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">An optimization based deep learning approach for human activity recognition in healthcare monitoring</dc:title><dc:creator>Aparna Kalyanasundaram</dc:creator><dc:creator>Ganesh Panathula</dc:creator><dc:subject>human activity recognition</dc:subject><dc:subject>healthcare monitoring</dc:subject><dc:subject>crayfish optimization algorithm</dc:subject><dc:subject>long short-term memory</dc:subject><dc:subject>wearable sensor data</dc:subject><dc:subject>feature reduction</dc:subject><dc:subject>hyperparameter optimization</dc:subject><dc:subject>WISDM</dc:subject><dc:subject>UCI-HAR</dc:subject><dc:subject>PAMAP2</dc:subject><dc:description xml:lang="en">Medical images are comprised of sensor measurements which help detect the characteristics of diseases. Computer-based analysis results in the early detection of diseases and suitable medications. Human activity recognition (HAR) is highly useful in applications related to medical care, fitness tracking, and patient data archiving. There are two kinds of data fed into the HAR system which are, image data and time series data of physical movements through accelerometers and gyroscopes present in smart devices. This study introduced crayfish optimization algorithm with long short term memory (COA-LSTM). The raw data is obtained from three datasets namely, WISDM, UCI-HAR, and PAMAP2 datasets; then, pre-processing helps in removal of unwanted information. The features from pre-processed data are reduced using principal component analysis and linear discriminant analysis (PCA-LDA). Finally, classification is performed using COA-LSTM where, the hyperparameters are fine-tuned with the help of COA. The suggested method achieves a classification accuracy of 98.23% for UCI-HAR dataset, whereas the existing techniques like convolutional neural network (CNN), multi-branch CNN-bidirectional LSTM, CNN with gated recurrent unit (GRU), ST-deep HAR, and Ensem-HAR obtain a classification accuracy of 91.98%, 96.37%, 96.20%, 97.7%, and 95.05%, respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i6.8000</dc:identifier><dc:identifier>10.11591/eei.v13i6.8000</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 6 (2024); 4236-4247</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/8000/3972</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>