Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Cyclic voltammetry readout circuitry for DNA biosensor application

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 1 (2021) · hlm. 86–92

DOI
10.11591/eei.v10i1.2507
ISSN
2089-3191, 2302-9285
Terbit
2021-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Cyclic voltammetry electrochemical biosensors reported a wide usage and applications for its fast response, able to be miniaturized and its sensitivity. However, the bulky, expensive and laboratory-based readout circuitry made it impossible to be used in the field-based environment. A miniaturized and portable readout circuitry for the DNA detection using hybridization technique had been design and developed in this work. It embedded with fabricated FR4 based sensor and produced respective current when the applied voltage was within the range of 0 to 0.5 V. The readout circuitry had been verified with five analysis environments. Bare Au with distilled water (dH2O), bare Au with ferricyanide reagent solution, DNA immobilization, DNA non-hybridization and DNA hybridization. All the results performed produced peak cathodic current when the applied input voltage is within 0.5 V to 3 V and hence proved that the miniaturized and portable readout circuitry is suitable to be implemented for cyclic voltammetry electrochemical biosensor.

Kata kunci

Jaringan kolaborasi para penulis

19 penulis · 65 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • Universiti Sains Malaysia
  • Penang Development Corporation
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohaiyedin IdrisUniversiti Teknologi MARA7
Nor Shahanim Mohamad HadisUniversiti Teknologi MARA5
Noormadinah AlliasUniversiti Teknologi MARA4
Mohd Faris Izzwan Mohd SayudziUniversiti Teknologi MARA4
M. H. RoslanUniversiti Teknologi MARA3
N. W. M. SaadPenang Development Corporation3
Zaim Zakwan AminuddinAfiliasi tidak diketahui3
Ahmad Asri Abd SamatUniversiti Teknologi MARA3
Han MingyingUniversiti Sains Malaysia2
Lyu TaoUniversiti Sains Malaysia2
Mohammad Nizam IbrahimUniversiti Teknologi MARA1
Samsul SetuminUniversiti Teknologi MARA1
Samihah AbdullahUniversiti Teknologi MARA1
Muhammad Ameerul Syafiqie Abdul SukorUniversiti Teknologi MARA1
Azwati AzminUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Cyclic voltammetry readout circuitry for DNA biosensor application</dc:title><dc:creator>Irni Hamiza Hamzah</dc:creator><dc:creator>Azman Ab Malik</dc:creator><dc:creator>Alhan Farhanah Abd Rahim</dc:creator><dc:creator>Zainal Hisham Che Soh</dc:creator><dc:subject>cyclic voltammetry</dc:subject><dc:subject>DNA biosensor</dc:subject><dc:subject>readout electronics</dc:subject><dc:subject>miniaturized electronics</dc:subject><dc:subject>portable biosensor</dc:subject><dc:subject>DNA hybridization</dc:subject><dc:subject>gold electrode</dc:subject><dc:subject>ferricyanide</dc:subject><dc:subject>cathodic current</dc:subject><dc:description xml:lang="en">Cyclic voltammetry electrochemical biosensors reported a wide usage and applications for its fast response, able to be miniaturized and its sensitivity. However, the bulky, expensive and laboratory-based readout circuitry made it impossible to be used in the field-based environment. A miniaturized and portable readout circuitry for the DNA detection using hybridization technique had been design and developed in this work. It embedded with fabricated FR4 based sensor and produced respective current when the applied voltage was within the range of 0 to 0.5 V. The readout circuitry had been verified with five analysis environments. Bare Au with distilled water (dH2O), bare Au with ferricyanide reagent solution, DNA immobilization, DNA non-hybridization and DNA hybridization. All the results performed produced peak cathodic current when the applied input voltage is within 0.5 V to 3 V and hence proved that the miniaturized and portable readout circuitry is suitable to be implemented for cyclic voltammetry electrochemical biosensor.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i1.2507</dc:identifier><dc:identifier>10.11591/eei.v10i1.2507</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 1 (2021); 86-92</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2507/1894</dc:relation></oai_dc:dc>