Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Proposition of local automatic algorithm for landmark detection in 3D cephalometry

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 2 (2021) · hlm. 707–715

DOI
10.11591/eei.v10i2.1827
ISSN
2089-3191, 2302-9285
Terbit
2021-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This study proposes a new contribution to solve the problem of automatic landmarks detection in three-dimensional cephalometry. 3D images obtained from CBCT (cone beam computed tomography) equipment were used for automatic identification of twelve landmarks. The proposed method is based on a local geometry and intensity criteria of skull structures. After the step of preprocessing and binarization, the algorithm segments the skull into three structures using the geometry information of nasal cavity and intensity information of the teeth. Each targeted landmark was detected using local geometrical information of the volume of interest containing this landmark. The ICC and confidence interval (95% CI) for each direction were 0, 91 (0.75 to 0.96) for x- direction; 0.92 (0.83 to 0.97) for y-direction; 0.92 (0.79 to 0.97) for z-direction. The mean error of detection was calculated using the Euclidian distance between the 3D coordinates of manually and automatically detected landmarks. The overall mean error of the algorithm was 2.76 mm with a standard deviation of 1.43 mm. Our proposed approach for automatic landmark identification in 3D cephalometric was capable of detecting 12 landmarks on 3D CBCT images which can be facilitate the use of 3D cephalometry to orthodontists.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 26 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Chouaib Doukkali University
  • University of Hassan II Casablanca
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abderrahim Beni‐HssaneChouaib Doukkali University4
Hamid El ByadChouaib Doukkali University3
Z. HatimChouaib Doukkali University3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Proposition of local automatic algorithm for landmark detection in 3D cephalometry</dc:title><dc:creator>Mohammed Ed-Dhahraouy</dc:creator><dc:creator>Hicham Riri</dc:creator><dc:creator>Manal Ezzahmouly</dc:creator><dc:creator>Abdelmajid Elmoutaouakkil</dc:creator><dc:creator>Hakima Aghoutan</dc:creator><dc:creator>Farid Bourzgui</dc:creator><dc:subject>automatic landmark detection</dc:subject><dc:subject>3D cephalometry</dc:subject><dc:subject>cone-beam computed tomography</dc:subject><dc:subject>skull segmentation</dc:subject><dc:subject>nasal cavity geometry</dc:subject><dc:subject>orthodontic diagnosis</dc:subject><dc:subject>3D facial imaging</dc:subject><dc:description xml:lang="en">This study proposes a new contribution to solve the problem of automatic landmarks detection in three-dimensional cephalometry. 3D images obtained from CBCT (cone beam computed tomography) equipment were used for automatic identification of twelve landmarks. The proposed method is based on a local geometry and intensity criteria of skull structures. After the step of preprocessing and binarization, the algorithm segments the skull into three structures using the geometry information of nasal cavity and intensity information of the teeth. Each targeted landmark was detected using local geometrical information of the volume of interest containing this landmark. The ICC and confidence interval (95% CI) for each direction were 0, 91 (0.75 to 0.96) for x- direction; 0.92 (0.83 to 0.97) for y-direction; 0.92 (0.79 to 0.97) for z-direction. The mean error of detection was calculated using the Euclidian distance between the 3D coordinates of manually and automatically detected landmarks. The overall mean error of the algorithm was 2.76 mm with a standard deviation of 1.43 mm. Our proposed approach for automatic landmark identification in 3D cephalometric was capable of detecting 12 landmarks on 3D CBCT images which can be facilitate the use of 3D cephalometry to orthodontists.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i2.1827</dc:identifier><dc:identifier>10.11591/eei.v10i2.1827</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 2 (2021); 707-715</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1827/2053</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>