Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Textile-based electrode for electrocardiography monitoring

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 6 (2020) · hlm. 2311–2318

DOI
10.11591/eei.v9i6.2198
ISSN
2089-3191, 2302-9285
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The increasing demand of smart garment for monitoring people’s health is due to comfortability, lightweight and flexibility properties of the textile could offer to the user. The textile-based electrocardiography (ECG) electrode is an alternative of commercially available silver/silver chloride (Ag/AgCl) electrode which could cause skin allergies to certain users and is not suitable for long-term monitoring electrode. In this paper, we report the performance of reduced graphene oxide (rGO) coated cotton fabric electrode to the effect of longevity and temperature. The ECG waveform and signal-to noise ratio (SNR) of the rGO-coated cotton electrodes were compared to that the performance of Ag/AgCl electrodes. The reliability characterization confirmed the rGO-coated cotton fabric conductance maintain at more than 80% even after 100 days of fabrication and the conductance measurement is increasing with respect to the temperature applied. The electrode shows lower in impedance value and the performance in acquiring ECG signal is comparable with the Ag/AgCl electrode. The vertical position rectangle-shaped electrode is recommended in measuring ECG signals. In conclusion, the rGO-coated cotton electrode with flexible dry-type electrode and excellent performance especially reliability and in capturing ECG signal had shown a promising result for further development.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 39 tautan kepenulisan bersama · 25 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Universiti Malaysia Terengganu
  • Swiss German University
  • TATI University College
  • Ho Chi Minh City University of Technology
  • University of Malaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Noor Syazwana SaharUniversity of Technology Malaysia4
Hanis Camelia MuharUniversity of Technology Malaysia2
Ameer Farhan Mohd ArzamanUniversiti Malaysia Terengganu1
Hayatul Safrah SallehUniversiti Malaysia Terengganu1
Abdul Mutalib EmbongUniversiti Malaysia Terengganu1
Kais Amir KadhimUniversiti Malaysia Terengganu1
Norzamziah AfzainizamTATI University College1
Loi Hoang Huy Phuoc PhamHo Chi Minh City University of Technology1
Nur Yuhanis Mohd NasirUniversity of Malaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Textile-based electrode for electrocardiography monitoring</dc:title><dc:creator>Syaidah Md Saleh</dc:creator><dc:creator>Nurul Ashikin Abdul-Kadir</dc:creator><dc:creator>Fauzan Khairi Che Harun</dc:creator><dc:creator>Dedy H. B. Wicaksono</dc:creator><dc:subject>electrocardiogram</dc:subject><dc:subject>reduced graphene oxide</dc:subject><dc:subject>cotton fabric</dc:subject><dc:subject>smart garments</dc:subject><dc:subject>wearable health monitoring</dc:subject><dc:subject>electrode reliability</dc:subject><dc:subject>electrode impedance</dc:subject><dc:subject>temperature dependence</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:subject>skin allergy</dc:subject><dc:description xml:lang="en">The increasing demand of smart garment for monitoring people’s health is due to comfortability, lightweight and flexibility properties of the textile could offer to the user. The textile-based electrocardiography (ECG) electrode is an alternative of commercially available silver/silver chloride (Ag/AgCl) electrode which could cause skin allergies to certain users and is not suitable for long-term monitoring electrode. In this paper, we report the performance of reduced graphene oxide (rGO) coated cotton fabric electrode to the effect of longevity and temperature. The ECG waveform and signal-to noise ratio (SNR) of the rGO-coated cotton electrodes were compared to that the performance of Ag/AgCl electrodes. The reliability characterization confirmed the rGO-coated cotton fabric conductance maintain at more than 80% even after 100 days of fabrication and the conductance measurement is increasing with respect to the temperature applied. The electrode shows lower in impedance value and the performance in acquiring ECG signal is comparable with the Ag/AgCl electrode. The vertical position rectangle-shaped electrode is recommended in measuring ECG signals. In conclusion, the rGO-coated cotton electrode with flexible dry-type electrode and excellent performance especially reliability and in capturing ECG signal had shown a promising result for further development.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i6.2198</dc:identifier><dc:identifier>10.11591/eei.v9i6.2198</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 6 (2020); 2311-2318</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2198/1814</dc:relation></oai_dc:dc>