Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Two-port network model of wind turbine generator for three-phase unbalanced distribution system load flow analysis

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 1 (2022) · hlm. 9–19

DOI
10.11591/eei.v11i1.3074
ISSN
2089-3191, 2302-9285
Terbit
2022-01-22
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

An unbalanced electric power system can occur due to unequal lines and/or loads in each phase of the system. For a system with a high level of unbalance, the assumption that the system is balanced becomes incorrect. For a case like this, the system must be analyzed using three-phase approaches because single-phase analysis techniques can no longer be used to obtain accurate results. Therefore, the development of three-phase models of all components of the electric power system, including the wind turbine generating system (WTGS), is very important so that the system can properly be analyzed and its performance can correctly be evaluated. This paper proposes a method to incorporate WTGS in a three-phase load flow analysis of an unbalanced distribution system. The proposed method is based on the previously published single-phase two-port network model. In this paper, the single-phase two-port network model is modified and extended so that it can be applied to unbalanced systems. The model is then included in the three-phase distribution system load flow (DSLF) analysis. The proposed method is validated using 12-node and 19-node distribution systems.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kho Hie KhweeTanjungpura University3
Ismail YusufTanjungpura University1
M. Iqbal ArsyadTanjungpura University1
Managam RajagukgukTanjungpura University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Two-port network model of wind turbine generator for three-phase unbalanced distribution system load flow analysis</dc:title><dc:creator>Rudy Gianto</dc:creator><dc:creator>Purwoharjono Purwoharjono</dc:creator><dc:subject>wind turbine generator</dc:subject><dc:subject>two-port network model</dc:subject><dc:subject>unbalanced distribution systems</dc:subject><dc:subject>wind power integration</dc:subject><dc:description xml:lang="en">An unbalanced electric power system can occur due to unequal lines and/or loads in each phase of the system. For a system with a high level of unbalance, the assumption that the system is balanced becomes incorrect. For a case like this, the system must be analyzed using three-phase approaches because single-phase analysis techniques can no longer be used to obtain accurate results. Therefore, the development of three-phase models of all components of the electric power system, including the wind turbine generating system (WTGS), is very important so that the system can properly be analyzed and its performance can correctly be evaluated. This paper proposes a method to incorporate WTGS in a three-phase load flow analysis of an unbalanced distribution system. The proposed method is based on the previously published single-phase two-port network model. In this paper, the single-phase two-port network model is modified and extended so that it can be applied to unbalanced systems. The model is then included in the three-phase distribution system load flow (DSLF) analysis. The proposed method is validated using 12-node and 19-node distribution systems.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-01-22</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i1.3074</dc:identifier><dc:identifier>10.11591/eei.v11i1.3074</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 1 (2022); 9-19</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3074/2452</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>