Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Investigation on the mass sensitivity of quartz crystal microbalance gas sensor using finite element simulation

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 2 (2019) · hlm. 460–469

DOI
10.11591/eei.v8i2.1521
ISSN
2089-3191, 2302-9285
Terbit
2019-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The increasing global trends in healthcare priorities towards improving the effectiveness of diagnostic procedure by utilizing a non-invasive method which is breath analysis. This will benefit in increasing treatment efficiency and also reducing healthcare costs. Breath is a simple technique where the sample are easily obtained and can be provided immediately. The most popular method that had been used in hospital are urine and blood. Contradict with breath, urine and blood take too much time to analyse the disease and a painful process. The detection technique of breath analysis is done by using electroacoustic wave sensor from piezoelectric substrate. This acoustic wave sensor has been used to detect the changes in the frequency where it will be used to detect the disease. Breath analysis is a technique where it uses an electronic nose (E-nose) as a device. E-nose consist of Quartz Crystal Microbalance (QCM) sensor in order to differentiate odor in human breath. QCM is a sensitive weighing device which have a high efficiency. AT-cut quartz was chosen as the piezoelectric material and aluminum as the electrode. The objective of this paper is to design and simulate a QCM sensor for breath analysis application. Other than that, it also to determine the important key parameters that influence the performance of breath analysis which is sensitivity and resonant frequency. QCM sensor is being simulate by using COMSOL Multiphysics software. This is to evaluate the behavior of QCM sensor in terms of Eigen frequency analysis. The simulated QCM sensor with quartz radius of 166 um resonates at 8.871 MHz. The sensitivity of the sensor is 0.167 MHz/ng after exposed to acetone gas which act as the breath marker for detection of diseases in exhaled breath. Hence, the proposed design can be used as a non-invasive approach for early detection of disease through breath analysis.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 81 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • International Islamic University Malaysia
  • National Institutes of Health
  • Yogyakarta State University
  • Jabil (United States)
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anis Nurashikin NordinInternational Islamic University Malaysia3
Nurul Fadzlin HasbullahInternational Islamic University Malaysia3
Nur Hanisah AzmiInternational Islamic University Malaysia2
Muhammad Irsyad SuhaimiJabil (United States)2
Lim Lai MingAfiliasi tidak diketahui2
Zambri SamsudinAfiliasi tidak diketahui2
Norfaizul Izwan NordinInternational Islamic University Malaysia2
Yusof AbdullahInternational Islamic University Malaysia2
M. Azim KhairiInternational Islamic University Malaysia2
Teddy Surya GunawanInternational Islamic University Malaysia1
Fatchul ArifinYogyakarta State University1
Zainihariyati Mohd ZainAfiliasi tidak diketahui1
Faisal Ahmed AssaigInternational Islamic University Malaysia1
Rozainanee Mohd ZainNational Institutes of Health1
Tamana BabaInternational Islamic University Malaysia1
Muhammad Hazeeq HusniInternational Islamic University Malaysia1
Farah Binti AhmadInternational Islamic University Malaysia1
A. S. MahadiInternational Islamic University Malaysia1
M.R. Mohd AsyrafInternational Islamic University Malaysia1
Muhammad Syazwan Bin Mohd YusofInternational Islamic University Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Investigation on the mass sensitivity of quartz crystal microbalance gas sensor using finite element simulation</dc:title><dc:creator>Aliza Aini Md Ralib</dc:creator><dc:creator>Nik Nursyahida Bt Nik Mohd Zamri</dc:creator><dc:creator>Ahmad Hafiz Faqruddin Hazadi</dc:creator><dc:creator>Rosminazuin Ab Rahim</dc:creator><dc:creator>Nor Farahidah Za’bah</dc:creator><dc:creator>Norazlina Bt Saidin</dc:creator><dc:subject>quartz crystal microbalance</dc:subject><dc:subject>gas sensors</dc:subject><dc:subject>mass sensitivity</dc:subject><dc:subject>breath analysis</dc:subject><dc:subject>electronic nose</dc:subject><dc:subject>AT-cut quartz</dc:subject><dc:subject>resonant frequency</dc:subject><dc:subject>acetone detection</dc:subject><dc:subject>non-invasive disease detection</dc:subject><dc:subject>finite element analysis</dc:subject><dc:description xml:lang="en">The increasing global trends in healthcare priorities towards improving the effectiveness of diagnostic procedure by utilizing a non-invasive method which is breath analysis. This will benefit in increasing treatment efficiency and also reducing healthcare costs. Breath is a simple technique where the sample are easily obtained and can be provided immediately. The most popular method that had been used in hospital are urine and blood. Contradict with breath, urine and blood take too much time to analyse the disease and a painful process. The detection technique of breath analysis is done by using electroacoustic wave sensor from piezoelectric substrate. This acoustic wave sensor has been used to detect the changes in the frequency where it will be used to detect the disease. Breath analysis is a technique where it uses an electronic nose (E-nose) as a device. E-nose consist of Quartz Crystal Microbalance (QCM) sensor in order to differentiate odor in human breath. QCM is a sensitive weighing device which have a high efficiency. AT-cut quartz was chosen as the piezoelectric material and aluminum as the electrode. The objective of this paper is to design and simulate a QCM sensor for breath analysis application. Other than that, it also to determine the important key parameters that influence the performance of breath analysis which is sensitivity and resonant frequency. QCM sensor is being simulate by using COMSOL Multiphysics software. This is to evaluate the behavior of QCM sensor in terms of Eigen frequency analysis. The simulated QCM sensor with quartz radius of 166 um resonates at 8.871 MHz. The sensitivity of the sensor is 0.167 MHz/ng after exposed to acetone gas which act as the breath marker for detection of diseases in exhaled breath. Hence, the proposed design can be used as a non-invasive approach for early detection of disease through breath analysis.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i2.1521</dc:identifier><dc:identifier>10.11591/eei.v8i2.1521</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 2 (2019); 460-469</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1521/1053</dc:relation></oai_dc:dc>