Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Simulation analysis of equivalent circuit model of skin-electrode impedance for transcutaneous electrical stimulation

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 4 (2021) · hlm. 1936–1943

DOI
10.11591/eei.v10i4.3080
ISSN
2089-3191, 2302-9285
Terbit
2021-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

For more than 50 years, transcutaneous electrical stimulation method has been used to cure the spinal cord injury, stroke or cerebral palsy. This method works by activating the excitable nerves, muscle fibers by electrical current stimulation through electrode to skin interface. Electrode to skin interface requires equivalent circuit to overcome the inability of measuring the skin resistivity directly. We have learned several previous models, which are from Lawler, Moineau and Keller and Kuhn. Unfortunately, Moineau model neglects the capacitance effect, while Lawler and Keller and Kuhn include capacitive and resistive nature of skin in their equivalent circuits. Both models consisted of only one parallel RC block. Therefore, this paper presents the simulation results of the proposed equivalent circuit model using two parallel RC circuits. Simulation of the proposed model is conducted in MATLAB 2015a and compared with two previous models using certain parameters. Results show that the proposed model obtained the impedance of 10.830 kΩ when it is simulated using 100Hz frequency, for Lawler model the impedance is 5.340 kΩ and Keller and Kuhn model the impedance obtained is 6.490 kΩ. The proposed model has the refined impedance compared with other models and is expected to deliver better electrical stimulation.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 20 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • President University
  • Manchester Metropolitan University
  • Politeknik Astra
  • Aalto University
  • Universitas Ahmad Dahlan
  • Mississippi College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan1
Dodi GarintoPoliteknik Astra1
Theodora ValerieAalto University1
Harki Apri YantoPoliteknik Astra1
Hendra Jaya TariganMississippi College1
Lydia AnggrainiPresident University1
Ali RospawanPresident University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Simulation analysis of equivalent circuit model of skin-electrode impedance for transcutaneous electrical stimulation</dc:title><dc:creator>Joni Welman Simatupang</dc:creator><dc:creator>Wilbert Wijaya</dc:creator><dc:creator>David Tyler</dc:creator><dc:creator>Clémentine Mavridis</dc:creator><dc:subject>transcutaneous electrical stimulation</dc:subject><dc:subject>skin-electrode interface</dc:subject><dc:subject>equivalent circuit model</dc:subject><dc:subject>skin impedance</dc:subject><dc:subject>parallel RC circuit</dc:subject><dc:subject>skin capacitance</dc:subject><dc:subject>spinal cord injury rehabilitation</dc:subject><dc:description xml:lang="en">For more than 50 years, transcutaneous electrical stimulation method has been used to cure the spinal cord injury, stroke or cerebral palsy. This method works by activating the excitable nerves, muscle fibers by electrical current stimulation through electrode to skin interface. Electrode to skin interface requires equivalent circuit to overcome the inability of measuring the skin resistivity directly. We have learned several previous models, which are from Lawler, Moineau and Keller and Kuhn. Unfortunately, Moineau model neglects the capacitance effect, while Lawler and Keller and Kuhn include capacitive and resistive nature of skin in their equivalent circuits. Both models consisted of only one parallel RC block. Therefore, this paper presents the simulation results of the proposed equivalent circuit model using two parallel RC circuits. Simulation of the proposed model is conducted in MATLAB 2015a and compared with two previous models using certain parameters. Results show that the proposed model obtained the impedance of 10.830 kΩ when it is simulated using 100Hz frequency, for Lawler model the impedance is 5.340 kΩ and Keller and Kuhn model the impedance obtained is 6.490 kΩ. The proposed model has the refined impedance compared with other models and is expected to deliver better electrical stimulation.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i4.3080</dc:identifier><dc:identifier>10.11591/eei.v10i4.3080</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 4 (2021); 1936-1943</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3080/2237</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>