Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optic disc localization using graph traversal algorithm along blood vessel in polar retinal image

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3301–3312

DOI
10.11591/eei.v11i6.3618
ISSN
2089-3191, 2302-9285
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The optic disc (OD) is an important landmark of the retina and its location is essential for computer-aided diagnosis of diabetic retinopathy and glaucoma. This paper presented a new method that applies the proposed graph traversal algorithm for vertical vascular infrastructure to detect root nodes representing the location of optical discs. The proposed algorithms were designed to process the terrific view of blood vessels from a polar image without depending on the prominent OD characteristic of circular/elliptical shape and brightness. Before constructing the vascular infrastructure, the new multi-scale and multi-orientation top-hat filters were proposed to properly approximate blood vessels of different sizes and directions. The proposed method provided efficiency and certainty for complex retinal images such as low contrast OD with low illumination and distorted OD shape due to complex vascular structure. The algorithms evaluation was performed on five public fundus image databases for retinal image analysis. Experimental results revealed that the proposed algorithm identified valid optical discs with high accuracy as 91.21%, 95.09%, 88.45%, 91.66%, and 95.01% for the five corresponding data sets and outperformed comparison methods.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ramkhamhaeng University
  • Mae Fah Luang University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optic disc localization using graph traversal algorithm along blood vessel in polar retinal image</dc:title><dc:creator>Annupan Rodtook</dc:creator><dc:creator>Sirikan Chucherd</dc:creator><dc:subject>optic disc localization</dc:subject><dc:subject>graph traversal algorithms</dc:subject><dc:subject>retinal vasculature</dc:subject><dc:subject>fundus image analysis</dc:subject><dc:subject>diabetic retinopathy</dc:subject><dc:subject>glaucoma</dc:subject><dc:description xml:lang="en">The optic disc (OD) is an important landmark of the retina and its location is essential for computer-aided diagnosis of diabetic retinopathy and glaucoma. This paper presented a new method that applies the proposed graph traversal algorithm for vertical vascular infrastructure to detect root nodes representing the location of optical discs. The proposed algorithms were designed to process the terrific view of blood vessels from a polar image without depending on the prominent OD characteristic of circular/elliptical shape and brightness. Before constructing the vascular infrastructure, the new multi-scale and multi-orientation top-hat filters were proposed to properly approximate blood vessels of different sizes and directions. The proposed method provided efficiency and certainty for complex retinal images such as low contrast OD with low illumination and distorted OD shape due to complex vascular structure. The algorithms evaluation was performed on five public fundus image databases for retinal image analysis. Experimental results revealed that the proposed algorithm identified valid optical discs with high accuracy as 91.21%, 95.09%, 88.45%, 91.66%, and 95.01% for the five corresponding data sets and outperformed comparison methods.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.3618</dc:identifier><dc:identifier>10.11591/eei.v11i6.3618</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3301-3312</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3618/3000</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>