Abstrak

This paper presents dynamic simulation and control of stand-alone doubly fed induction generator (DFIG) loaded with 3-phase induction motors (IMs). The study reveals that direct on-line starting of large IMs causes a large voltage sag across the generator terminals as the starting current drawn reaches up to 8-9 times the rated load current. Traditionally, this problem has tackled by oversizing of the generator or employment of special starters, under the pretext of mitigating voltage sag. This work explores ways that the starting current can be reduced economically by applying constant V/f control side by side with indirect field-oriented control (FOC) applied on the rotor side converter of the DFIG. This methodology enables starting of larger IMs and mitigation of voltage sag that occurs during the start-up period. Two different rating of IMs loaded with speed-squared mechanical torque are mainly considered. Simulation results of the system behavior under study confirm the capability of the proposed control.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 25 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Benha University
  • Cairo University
  • The Future University
  • Arab Academy for Science, Technology, and Maritime Transport
  • Universitas Ahmad Dahlan
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan4
Mohamed SharawyBenha University4
Youssuf ElthokabyBenha University1
Ibrahim AbdelsalamArab Academy for Science, Technology, and Maritime Transport1
Islam Mohamed AbdealqaweeBenha University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Starting of induction motor fed with stand-alone DFIG</dc:title><dc:creator>M. Sharawy</dc:creator><dc:creator>Adel Shaltout</dc:creator><dc:creator>Naser Abdel‐Rahim</dc:creator><dc:creator>Mahmoud A. Al-Ahmar</dc:creator><dc:creator>Omar El-Sayed Mohammed Youssef</dc:creator><dc:subject>doubly fed induction generator</dc:subject><dc:subject>induction motor starting</dc:subject><dc:subject>voltage sag mitigation</dc:subject><dc:subject>V/f control</dc:subject><dc:subject>indirect field oriented control</dc:subject><dc:subject>rotor side converter</dc:subject><dc:subject>starting current reduction</dc:subject><dc:description xml:lang="en">This paper presents dynamic simulation and control of stand-alone doubly fed induction generator (DFIG) loaded with 3-phase induction motors (IMs). The study reveals that direct on-line starting of large IMs causes a large voltage sag across the generator terminals as the starting current drawn reaches up to 8-9 times the rated load current. Traditionally, this problem has tackled by oversizing of the generator or employment of special starters, under the pretext of mitigating voltage sag. This work explores ways that the starting current can be reduced economically by applying constant V/f control side by side with indirect field-oriented control (FOC) applied on the rotor side converter of the DFIG. This methodology enables starting of larger IMs and mitigation of voltage sag that occurs during the start-up period. Two different rating of IMs loaded with speed-squared mechanical torque are mainly considered. Simulation results of the system behavior under study confirm the capability of the proposed control.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i5.3161</dc:identifier><dc:identifier>10.11591/eei.v10i5.3161</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 5 (2021); 2414-2423</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3161/2310</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>