Akses terbuka
Jurnal
SINTA 1
Variance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation
Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3061–3068
ISSN 2089-3191, 2302-9285
Terbit 2022-12-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This paper discusses the need for variance reduction in simulations in order to reduce the time required to compute a simulation. The large and complex network is commonly evaluated using a large-scale Monte Carlo simulation. Unfortunately, due to the different sizes of the network, it takes some time to complete a simulation. However, variance reduction techniques (VRT) can help to solve the issues. The effect of VRT changes the behaviors of a simulation, particularly the time required to run the simulation. To evaluate the reliability indices, two sequential Monte Carlo (SMC) methods are used. SMC with VRT and SMC without VRT are the two options. The presence of VRT in the simulation distinguishes the two simulations. Finally, reliability indices: system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), and customer average interruption duration index (CAIDI) will be calculated at the end of the simulation to determine the efficiency for the SMC with and without VRT. Overall, the SMC with VRT is more efficient because it is more convenient and saves time than the SMC without VRT.
Jaringan kolaborasi para penulis
12 penulis ·
30 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universiti Malaysia Pahang Al-Sultan Abdullah International Islamic University Malaysia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Variance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation</dc:title><dc:creator>Nur Nabihah Rusyda Roslan</dc:creator><dc:creator>NoorFatin Farhanie Mohd Fauzi</dc:creator><dc:creator>Mohd Ikhwan Muhammad Ridzuan</dc:creator><dc:subject>variance reduction</dc:subject><dc:subject>sequential Monte Carlo simulation</dc:subject><dc:subject>distribution network reliability</dc:subject><dc:subject>reliability index</dc:subject><dc:subject>SAIFI</dc:subject><dc:subject>SAIDI</dc:subject><dc:subject>CAIDI</dc:subject><dc:subject>simulation efficiency</dc:subject><dc:description xml:lang="en">This paper discusses the need for variance reduction in simulations in order to reduce the time required to compute a simulation. The large and complex network is commonly evaluated using a large-scale Monte Carlo simulation. Unfortunately, due to the different sizes of the network, it takes some time to complete a simulation. However, variance reduction techniques (VRT) can help to solve the issues. The effect of VRT changes the behaviors of a simulation, particularly the time required to run the simulation. To evaluate the reliability indices, two sequential Monte Carlo (SMC) methods are used. SMC with VRT and SMC without VRT are the two options. The presence of VRT in the simulation distinguishes the two simulations. Finally, reliability indices: system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), and customer average interruption duration index (CAIDI) will be calculated at the end of the simulation to determine the efficiency for the SMC with and without VRT. Overall, the SMC with VRT is more efficient because it is more convenient and saves time than the SMC without VRT.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.3950</dc:identifier><dc:identifier>10.11591/eei.v11i6.3950</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3061-3068</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3950/2974</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Roslan, N. N. R., Fauzi, N. F. M., & Ridzuan, M. I. M. (2022). Variance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation. Bulletin of Electrical Engineering and Informatics, 11(6), 3061–3068. https://doi.org/10.11591/eei.v11i6.3950
Salin
IEEE
N. N. R. Roslan, N. F. M. Fauzi, and M. I. M. Ridzuan, “Variance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation,” Bulletin of Electrical Engineering and Informatics, vol. 11, no. 6, pp. 3061–3068, 2022, doi: 10.11591/eei.v11i6.3950.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.