Abstrak

is paper proposed the integral-proportional-derivative (I-PD) as an extension of the conventional proportional-integral-derivative (PID) method that has been used in many brushless direct current (BLDC) applications to control the BLDC motor that can deal with desired speed (reference) changes. It has elucidated a comprehensive comparative analysis between PID, intending to delineate the most efficacious control approach based on a thorough evaluation. This paper scrutinizes four principal methods: proportional-integral (PI), integral-proportional (I-P), PID, and I-PD. Our findings indicate that in the presence of voltage spike constraints, I-P or I-PD emerges as the optimum choice for both four-pole and six-pole motors. Where maximum difference (MaxDiff) is the principal consideration, PI, and I-P are identified as the most suitable methods. Conversely, when the primary objective is to minimize root mean square error (RMSE), PI proves superior for four-pole motors, while PID is preferable for six-pole types. Notably, I-P demonstrates excellent performance in terms of settling time for both motor types. In summation, I-P stands out as the preeminent choice if the objective is to select a singular method that ensures optimal performance across all parameters for a four-pole or six-pole motor.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Bandung Institute of Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Berlian SitorusTanjungpura University2
Yandri YandriTanjungpura University1
Sukandar SukandarBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Integral-proportional derivative approach for brushless direct current motor speed control</dc:title><dc:creator>Seno Darmawan Panjaitan</dc:creator><dc:creator>Hendro Priyatman</dc:creator><dc:creator>Supriono Supriono</dc:creator><dc:creator>Muhammad Revaldi Frizky</dc:creator><dc:subject>brushless DC motor</dc:subject><dc:subject>speed control</dc:subject><dc:subject>PID control</dc:subject><dc:subject>PI controller</dc:subject><dc:subject>settling time</dc:subject><dc:subject>root mean square error</dc:subject><dc:description xml:lang="en">is paper proposed the integral-proportional-derivative (I-PD) as an extension of the conventional proportional-integral-derivative (PID) method that has been used in many brushless direct current (BLDC) applications to control the BLDC motor that can deal with desired speed (reference) changes. It has elucidated a comprehensive comparative analysis between PID, intending to delineate the most efficacious control approach based on a thorough evaluation. This paper scrutinizes four principal methods: proportional-integral (PI), integral-proportional (I-P), PID, and I-PD. Our findings indicate that in the presence of voltage spike constraints, I-P or I-PD emerges as the optimum choice for both four-pole and six-pole motors. Where maximum difference (MaxDiff) is the principal consideration, PI, and I-P are identified as the most suitable methods. Conversely, when the primary objective is to minimize root mean square error (RMSE), PI proves superior for four-pole motors, while PID is preferable for six-pole types. Notably, I-P demonstrates excellent performance in terms of settling time for both motor types. In summation, I-P stands out as the preeminent choice if the objective is to select a singular method that ensures optimal performance across all parameters for a four-pole or six-pole motor.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i5.7755</dc:identifier><dc:identifier>10.11591/eei.v13i5.7755</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 5 (2024); 3112-3120</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7755/3863</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>