Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Enhanced real-time glaucoma diagnosis: dual deep learning approach

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 3 (2025) · hlm. 1846–1857

DOI
10.11591/eei.v14i3.8495
ISSN
2089-3191, 2302-9285
Terbit
2025-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Effective management of glaucoma is essential for preventing irreversible vision loss. This study introduces a novel deep learning-based network designed to enhance performance while minimizing computational complexity. The system comprises two models: the first is a hybrid model combining a customized U-Net architecture integrated with you only look at coefficients (YOLACT) is utilized to achieve accurate segmentation of the optic disc (OD) and optic cup (OC), providing detailed diagnostic insights for ophthalmologists. The second model employs you only look once version 5 (YOLOv5) for real-time glaucoma prediction, delivering outstanding performance with an accuracy of 97.89% and F1 score of 98% on the primary dataset. On an independent dataset without further training, the model achieved 96% accuracy, with sensitivity and specificity of 98.9% and 93.3%, respectively. These results highlight the model's robustness, generalizability, and adaptability, demonstrating its potential for effective glaucoma screening and early detection in diverse clinical environments. This approach offers a promising advancement in improving the accessibility and efficiency of glaucoma management.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Helwan University
  • Higher Technological Institute
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Enhanced real-time glaucoma diagnosis: dual deep learning approach</dc:title><dc:creator>Momen Hesham</dc:creator><dc:creator>Ghada Kareem</dc:creator><dc:creator>Marwa M. A. Hadhoud</dc:creator><dc:subject>glaucoma diagnosis</dc:subject><dc:subject>optic disc segmentation</dc:subject><dc:subject>optic cup segmentation</dc:subject><dc:subject>U-Net</dc:subject><dc:subject>YOLACT</dc:subject><dc:subject>YOLOv5</dc:subject><dc:subject>glaucoma screening</dc:subject><dc:subject>computational efficiency</dc:subject><dc:description xml:lang="en">Effective management of glaucoma is essential for preventing irreversible vision loss. This study introduces a novel deep learning-based network designed to enhance performance while minimizing computational complexity. The system comprises two models: the first is a hybrid model combining a customized U-Net architecture integrated with you only look at coefficients (YOLACT) is utilized to achieve accurate segmentation of the optic disc (OD) and optic cup (OC), providing detailed diagnostic insights for ophthalmologists. The second model employs you only look once version 5 (YOLOv5) for real-time glaucoma prediction, delivering outstanding performance with an accuracy of 97.89% and F1 score of 98% on the primary dataset. On an independent dataset without further training, the model achieved 96% accuracy, with sensitivity and specificity of 98.9% and 93.3%, respectively. These results highlight the model's robustness, generalizability, and adaptability, demonstrating its potential for effective glaucoma screening and early detection in diverse clinical environments. This approach offers a promising advancement in improving the accessibility and efficiency of glaucoma management.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i3.8495</dc:identifier><dc:identifier>10.11591/eei.v14i3.8495</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 3 (2025); 1846-1857</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/8495/4208</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>