Jurnal
SINTA 1
Modeling of Power Losses Caused by Hidden Tree-Related High Impedance Faults
Bulletin of Electrical Engineering and Informatics · Vol. 5 No. 4 (2016) · hlm. 390–402
ISSN 2089-3191, 2302-9285
Terbit 2016-12-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
The great majority of overhead distribution systems in urban and rural areas of countries such as Australia, Iran and etc., are in interfering with vegetation. This phenomena leads to high impedance faults (HIFs) which not produce enough fault current to be detectable and consequently causes electrical energy losses. In this paper, according to experimental data obtained from measurements, the effective factors in power losses caused by trees are studied and a new numerical model of power loss is presented so as to reflect the effects of environmental conditions and biological classification. The base of this method is according to Samuelson theory. In proposed algorithm, the impacts of species, short-term environmental conditions (temperature and humidity) and long-term environmental conditions (Seasonal variations in physiology) on the power loss estimation are fully considered. Experimental investigations on a real low voltage (380 V) and medium voltage (20 kV) distribution network verify the algorithm’s operation.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Lorestan University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Modeling of Power Losses Caused by Hidden Tree-Related High Impedance Faults</dc:title><dc:creator>Nooshin Bahador</dc:creator><dc:creator>A.H. Lotfi</dc:creator><dc:subject>high impedance faults</dc:subject><dc:subject>power losses</dc:subject><dc:subject>overhead distribution networks</dc:subject><dc:subject>vegetation interference</dc:subject><dc:subject>power loss modeling</dc:subject><dc:subject>tree species effects</dc:subject><dc:subject>temperature and humidity effects</dc:subject><dc:subject>low-voltage distribution</dc:subject><dc:subject>medium-voltage distribution</dc:subject><dc:description xml:lang="en">The great majority of overhead distribution systems in urban and rural areas of countries such as Australia, Iran and etc., are in interfering with vegetation. This phenomena leads to high impedance faults (HIFs) which not produce enough fault current to be detectable and consequently causes electrical energy losses. In this paper, according to experimental data obtained from measurements, the effective factors in power losses caused by trees are studied and a new numerical model of power loss is presented so as to reflect the effects of environmental conditions and biological classification. The base of this method is according to Samuelson theory. In proposed algorithm, the impacts of species, short-term environmental conditions (temperature and humidity) and long-term environmental conditions (Seasonal variations in physiology) on the power loss estimation are fully considered. Experimental investigations on a real low voltage (380 V) and medium voltage (20 kV) distribution network verify the algorithm’s operation.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v5i4.567</dc:identifier><dc:identifier>10.11591/eei.v5i4.567</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 5 No 4 (2016); 390-402</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>http://beei.org/index.php/EEI/article/download/567/988</dc:relation></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
1 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Bahador, N., & Lotfi, A. (2016). Modeling of Power Losses Caused by Hidden Tree-Related High Impedance Faults. Bulletin of Electrical Engineering and Informatics, 5(4), 390–402. https://doi.org/10.11591/eei.v5i4.567
Salin
IEEE
N. Bahador and A. Lotfi, “Modeling of Power Losses Caused by Hidden Tree-Related High Impedance Faults,” Bulletin of Electrical Engineering and Informatics, vol. 5, no. 4, pp. 390–402, 2016, doi: 10.11591/eei.v5i4.567.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.