Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A comprehensive overview of the ADALINE method applied to rapid voltage sags detection in multi-motors drive systems

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3136–3146

DOI
10.11591/eei.v11i6.4141
ISSN
2089-3191, 2302-9285
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Several strategies have been developed for identifying power quality issues, monitoring them, and compensating for relevant disturbances. In this field, online estimate of amplitudes and phase angles of network voltages and currents is commonly used. The adaptive linear neuron (ADALINE)-based voltage sag detection algorithm with least mean square (LMS) adaptation allows for rapid convergence of estimate techniques based on artificial neural networks (ANN). This approach has the advantage of being straightforward to implement on hardware and based on simple calculations (essentially multiply and accumulate "MAC"). This paper gives a comparison of the performance of two ADALINE approaches ("with" and "without" error supervision) for detecting and estimating voltage dips. The described techniques and models of a two-coupled motor system were implemented in MATLAB/Simulink/SimPowerSystems to run simulations under various fault scenarios in order to create the three-phase voltage sag alarm signal. The simulation outcomes are presented and debated.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 29 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université Hassan 1er
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Elhassane AbdelmounimUniversité Hassan 1er10
Mhamed MadarkUniversité Hassan 1er7
Bouchaib RachedUniversité Hassan 1er7
Mohammed El MalahUniversité Hassan 1er6
Mustapha El HaroussiAfiliasi tidak diketahui4
M'hammed GuisserUniversité Hassan 1er1
Mustapha Es-SemyhyUniversité Hassan 1er1
Mohammed El HaissoufUniversité Hassan 1er1
Elhabib LotfiUniversité Hassan 1er1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A comprehensive overview of the ADALINE method applied to rapid voltage sags detection in multi-motors drive systems</dc:title><dc:creator>Mounir Bensaid</dc:creator><dc:creator>Abdellfattah Ba-Razzouk</dc:creator><dc:creator>Mustapha Elharoussi</dc:creator><dc:subject>ADALINE</dc:subject><dc:subject>voltage sag detection</dc:subject><dc:subject>voltage sag</dc:subject><dc:subject>multi-motor drive systems</dc:subject><dc:subject>power quality</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>fault detection</dc:subject><dc:description xml:lang="en">Several strategies have been developed for identifying power quality issues, monitoring them, and compensating for relevant disturbances. In this field, online estimate of amplitudes and phase angles of network voltages and currents is commonly used. The adaptive linear neuron (ADALINE)-based voltage sag detection algorithm with least mean square (LMS) adaptation allows for rapid convergence of estimate techniques based on artificial neural networks (ANN). This approach has the advantage of being straightforward to implement on hardware and based on simple calculations (essentially multiply and accumulate "MAC"). This paper gives a comparison of the performance of two ADALINE approaches ("with" and "without" error supervision) for detecting and estimating voltage dips. The described techniques and models of a two-coupled motor system were implemented in MATLAB/Simulink/SimPowerSystems to run simulations under various fault scenarios in order to create the three-phase voltage sag alarm signal. The simulation outcomes are presented and debated.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4141</dc:identifier><dc:identifier>10.11591/eei.v11i6.4141</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3136-3146</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4141/2983</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>