Electrical active power optimization of the SEIG-WTS based on perturb and observe method

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 1 (2025) · hlm. 96–107

DOI
10.11591/eei.v14i1.6940
ISSN
2089-3191, 2302-9285
Terbit
2025-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper proposes an electrical active power optimization for self-excited induction generator-wind turbine system (SEIG-WTS) using a perturb and observe (PO)-based maximum power point tracking. The main advantage is the optimization of the SEIG active power of SEIG-WTS and the simply practical implementation with rotor speed sensor, current sensor and three phase inverter. The active power optimization of SEIG-WTS is achieved by perturbing angular magnetic field speed with stator reference voltage. To test the effectiveness of the proposal, numeric simulations were carried out under very challenging conditions with wind speed profile in steps and actual wind speed profile. The proposal reaches the maximum power in 7 seconds for hardest condition when the system works at high rotor speed. The proposal is useful for the development of maximum power point tracking control (MPPT) controllers due to its simplicity in implementation.This paper proposes an electrical active power optimization for self-excited induction generator-wind turbine system (SEIG-WTS) using a perturb and observe (PO)-based maximum power point tracking. The main advantage is the optimization of the SEIG active power of SEIG-WTS and the simply practical implementation with rotor speed sensor, current sensor and three phase inverter. The active power optimization of SEIG-WTS is achieved by perturbing angular magnetic field speed with stator reference voltage. To test the effectiveness of the proposal, numeric simulations were carried out under very challenging conditions with wind speed profile in steps and actual wind speed profile. The proposal reaches the maximum power in 7 seconds for hardest condition when the system works at high rotor speed. The proposal is useful for the development of maximum power point tracking control (MPPT) controllers due to its simplicity in implementation.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National University of Engineering
  • Universidad Nacional del Callao
  • Universidad Nacional de Juliaca
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Electrical active power optimization of the SEIG-WTS based on perturb and observe method</dc:title><dc:creator>Mario G. Borja Borja</dc:creator><dc:creator>Sergio Lescano</dc:creator><dc:creator>Sally Torres Alvarado</dc:creator><dc:creator>Ubaldo Yancachajlla Tito</dc:creator><dc:creator>Jaime E. Luyo</dc:creator><dc:subject>self-excited induction generator</dc:subject><dc:subject>wind turbine systems</dc:subject><dc:subject>maximum power point tracking</dc:subject><dc:subject>perturb and observe</dc:subject><dc:subject>wind energy conversion</dc:subject><dc:subject>three-phase inverter</dc:subject><dc:subject>wind profiles</dc:subject><dc:description xml:lang="en">This paper proposes an electrical active power optimization for self-excited induction generator-wind turbine system (SEIG-WTS) using a perturb and observe (PO)-based maximum power point tracking. The main advantage is the optimization of the SEIG active power of SEIG-WTS and the simply practical implementation with rotor speed sensor, current sensor and three phase inverter. The active power optimization of SEIG-WTS is achieved by perturbing angular magnetic field speed with stator reference voltage. To test the effectiveness of the proposal, numeric simulations were carried out under very challenging conditions with wind speed profile in steps and actual wind speed profile. The proposal reaches the maximum power in 7 seconds for hardest condition when the system works at high rotor speed. The proposal is useful for the development of maximum power point tracking control (MPPT) controllers due to its simplicity in implementation.This paper proposes an electrical active power optimization for self-excited induction generator-wind turbine system (SEIG-WTS) using a perturb and observe (PO)-based maximum power point tracking. The main advantage is the optimization of the SEIG active power of SEIG-WTS and the simply practical implementation with rotor speed sensor, current sensor and three phase inverter. The active power optimization of SEIG-WTS is achieved by perturbing angular magnetic field speed with stator reference voltage. To test the effectiveness of the proposal, numeric simulations were carried out under very challenging conditions with wind speed profile in steps and actual wind speed profile. The proposal reaches the maximum power in 7 seconds for hardest condition when the system works at high rotor speed. The proposal is useful for the development of maximum power point tracking control (MPPT) controllers due to its simplicity in implementation.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i1.6940</dc:identifier><dc:identifier>10.11591/eei.v14i1.6940</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 1 (2025); 96-107</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6940/4020</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>