Abstrak

In order to maintain the technical leadership of the economic sector in any nation, there is currently a greater focus on guaranteeing the fail-safe operation of electrical networks and electrical equipment. This paper presents a model for evaluating the fault location procedure based on computer simulation in MATLAB/Simulink of complex 6(10)-35 kV power line systems. The proposed algorithm for preprocessing electrical network signals in normal and emergency modes uses a negative statistical correlation of all possible electrical parameters, while the resulting percentage errors when estimating the location of the fault are within acceptable limits. Algorithms and significant parameters have been determined for effectively carrying out the procedure for searching for the location of a fault through the use of modeling programs, namely: zero-sequence voltage, negative-sequence voltage, initial current value. and the positive sequence voltage is the transition resistance at the accident site. An assessment of the results of preliminary modeling may indicate that devices for finding the location of a fault in the 6(10)-35 kV electrical network will be able to use information obtained about the object using the developed methodology, adjust calculation algorithms and take into account the operating modes of the electrical network.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 14 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Akhmet Baitursynuly Kostanay Regional University
  • L. N. Gumilyov Eurasian National University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Uspanov Azamat AkhmetulyAkhmet Baitursynuly Kostanay Regional University4

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Modeling 6(10)-35 kV electrical network for fault location via negative correlation</dc:title><dc:creator>S. K. Sheryazov</dc:creator><dc:creator>A. I. Uspanova</dc:creator><dc:creator>Jeļena Titko</dc:creator><dc:creator>Igor Koshkin</dc:creator><dc:creator>Arman Utegulov</dc:creator><dc:subject>fault location</dc:subject><dc:subject>negative correlation</dc:subject><dc:subject>power line protection</dc:subject><dc:subject>zero-sequence voltage</dc:subject><dc:subject>negative sequence voltage</dc:subject><dc:subject>positive sequence voltage</dc:subject><dc:subject>transition resistance</dc:subject><dc:subject>network operating modes</dc:subject><dc:subject>Simulink modeling</dc:subject><dc:description xml:lang="en">In order to maintain the technical leadership of the economic sector in any nation, there is currently a greater focus on guaranteeing the fail-safe operation of electrical networks and electrical equipment. This paper presents a model for evaluating the fault location procedure based on computer simulation in MATLAB/Simulink of complex 6(10)-35 kV power line systems. The proposed algorithm for preprocessing electrical network signals in normal and emergency modes uses a negative statistical correlation of all possible electrical parameters, while the resulting percentage errors when estimating the location of the fault are within acceptable limits. Algorithms and significant parameters have been determined for effectively carrying out the procedure for searching for the location of a fault through the use of modeling programs, namely: zero-sequence voltage, negative-sequence voltage, initial current value. and the positive sequence voltage is the transition resistance at the accident site. An assessment of the results of preliminary modeling may indicate that devices for finding the location of a fault in the 6(10)-35 kV electrical network will be able to use information obtained about the object using the developed methodology, adjust calculation algorithms and take into account the operating modes of the electrical network.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i1.7544</dc:identifier><dc:identifier>10.11591/eei.v14i1.7544</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 1 (2025); 60-72</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7544/4017</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>