Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Arrhythmia classification using CMF-AFF based on electrocardiogram in field programmable gate array device

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 2 (2025) · hlm. 1190–1201

DOI
10.11591/eei.v14i2.8748
ISSN
2089-3191, 2302-9285
Terbit
2025-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Arrhythmia classification is categorization of irregular heart rhythms depending on patterns detected in electrocardiogram (ECG) signals assist in treatment and diagnosis of cardiac conditions. ECG evaluates heart’s electrical activity to diagnose various heart conditions, but it is affected by interference or noise. ECG’s signal filtering is essential pre-processing stage that minimizes noise and highlights wave characteristics in ECG data. However, digital filters are normally constructed by multiplying coefficient and then multiplying value given as feedback which leads to more power and area consumption. To solve these issues, coefficient memory compression (CMC) technique is proposed with an adaptive FIR filter (AFF) to achieve low area and low power dissipation by compressing memory requirements in a field programmable gate array (FPGA). An adaptive FIR filter is employed to effectively minimize noise like baseline noise, muscle contraction noise, and low-frequency noise. The performance of CMC-AFF is analyzed in terms of look up table (LUT), register, digital signal processing (DSP), power, and global buffer (BufG). The proposed approach achieves a low power consumption of 0.012 W in Zed Board Zynq7000 AP system on chip (SoC) FPGA device compared to existing techniques like collateral and sequence approaches using Bartlet filter and low-power ECG processor using Bartlet filter respectively.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 11 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. MekalaAfiliasi tidak diketahui1
G. Sankar BabuAfiliasi tidak diketahui1
S. NatarjanAfiliasi tidak diketahui1
N. SrinivasanAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Arrhythmia classification using CMF-AFF based on electrocardiogram in field programmable gate array device</dc:title><dc:creator>Nalavade Revanth</dc:creator><dc:creator>Maria Anto Bennet</dc:creator><dc:subject>arrhythmia classification</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>adaptive FIR filter</dc:subject><dc:subject>FPGA implementation</dc:subject><dc:subject>low power consumption</dc:subject><dc:subject>ECG noise reduction</dc:subject><dc:subject>baseline noise</dc:subject><dc:subject>Zynq-7000 SoC</dc:subject><dc:description xml:lang="en">Arrhythmia classification is categorization of irregular heart rhythms depending on patterns detected in electrocardiogram (ECG) signals assist in treatment and diagnosis of cardiac conditions. ECG evaluates heart’s electrical activity to diagnose various heart conditions, but it is affected by interference or noise. ECG’s signal filtering is essential pre-processing stage that minimizes noise and highlights wave characteristics in ECG data. However, digital filters are normally constructed by multiplying coefficient and then multiplying value given as feedback which leads to more power and area consumption. To solve these issues, coefficient memory compression (CMC) technique is proposed with an adaptive FIR filter (AFF) to achieve low area and low power dissipation by compressing memory requirements in a field programmable gate array (FPGA). An adaptive FIR filter is employed to effectively minimize noise like baseline noise, muscle contraction noise, and low-frequency noise. The performance of CMC-AFF is analyzed in terms of look up table (LUT), register, digital signal processing (DSP), power, and global buffer (BufG). The proposed approach achieves a low power consumption of 0.012 W in Zed Board Zynq7000 AP system on chip (SoC) FPGA device compared to existing techniques like collateral and sequence approaches using Bartlet filter and low-power ECG processor using Bartlet filter respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i2.8748</dc:identifier><dc:identifier>10.11591/eei.v14i2.8748</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 2 (2025); 1190-1201</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/8748/4129</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>