Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Advance technique for online condition monitoring of surge arresters

Bulletin of Electrical Engineering and Informatics · Vol. 14 No. 4 (2025) · hlm. 2526–2536

DOI
10.11591/eei.v14i4.9457
ISSN
2089-3191, 2302-9285
Terbit
2025-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Gapless surge arresters (GLSA) constructed with zinc oxide (ZnO) element is connected in electrical power system for protection against surge voltage. For condition monitoring of GLSA conventionally offline and online techniques are available. However, offline techniques are not much useful as it requires system shutdown and hence online techniques are more useful. Online surge arrester monitoring technique based on leakage current analysis is adopted by all stakeholders. However, in this method supply system harmonics plays major roles in measurement accuracy to determine health index. In this paper improved health monitoring indexes for GLSA diagnostic based on ratios of leakage current components has been proposed. The ageing process has been done with application of lightning Impulse current, surface contamination due to salt fog, temperature effect, and moisture ingress. Various experimental tests have been carried out on porcelain and polymer housed surge arresters to evaluate the ability of proposed method. Obtained results of 9 kV, 18 kV, and 30 kV healthy and degraded metal oxide GLSAs have been shown the viability of improved health indexes on surge arrester condition monitoring procedures. The experimental investigation and discussion of the obtained results reflects sufficient and effective trails to utility engineers to determine health of surge arresters and able to effectively schedule further maintenance plan.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Charotar University of Science and Technology
  • Parul University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Advance technique for online condition monitoring of surge arresters</dc:title><dc:creator>Anil S. Khopkar</dc:creator><dc:creator>Kartik S. Pandya</dc:creator><dc:subject>zinc oxide surge arrester</dc:subject><dc:subject>online condition monitoring</dc:subject><dc:subject>health indicators</dc:subject><dc:subject>moisture ingress</dc:subject><dc:subject>maintenance scheduling</dc:subject><dc:description xml:lang="en">Gapless surge arresters (GLSA) constructed with zinc oxide (ZnO) element is connected in electrical power system for protection against surge voltage. For condition monitoring of GLSA conventionally offline and online techniques are available. However, offline techniques are not much useful as it requires system shutdown and hence online techniques are more useful. Online surge arrester monitoring technique based on leakage current analysis is adopted by all stakeholders. However, in this method supply system harmonics plays major roles in measurement accuracy to determine health index. In this paper improved health monitoring indexes for GLSA diagnostic based on ratios of leakage current components has been proposed. The ageing process has been done with application of lightning Impulse current, surface contamination due to salt fog, temperature effect, and moisture ingress. Various experimental tests have been carried out on porcelain and polymer housed surge arresters to evaluate the ability of proposed method. Obtained results of 9 kV, 18 kV, and 30 kV healthy and degraded metal oxide GLSAs have been shown the viability of improved health indexes on surge arrester condition monitoring procedures. The experimental investigation and discussion of the obtained results reflects sufficient and effective trails to utility engineers to determine health of surge arresters and able to effectively schedule further maintenance plan.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2025-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v14i4.9457</dc:identifier><dc:identifier>10.11591/eei.v14i4.9457</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 14 No 4 (2025); 2526-2536</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/9457/4267</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>